Key result
Adjusting LVAD to high-speed settings significantly reduced NT-proBNP release during exercise (P<.01) and improved maximum workload (P<.05), but did not significantly increase 6MWT distance (P=.10).
Why the study?
Does higher LVAD pump speed improve exercise tolerance and reduce markers of wall stress in patients with end-stage heart failure?
RCT (n=10)
Does higher LVAD pump speed improve exercise tolerance and reduce markers of wall stress in patients with end-stage heart failure?
Increasing LVAD pump speed reduces myocardial wall stress as measured by NT-proBNP but does not significantly improve exercise tolerance.
High-speed LVAD settings reduce NT-proBNP release without improving 6MWT distance; extends hemodynamic findings but leaves functional benefit unconfirmed.
INTRODUCTION: Left ventricular assist devices are crucial in rehabilitation of patients with end-stage heart failure. Whether cardiopulmonary function is enhanced with higher pump output is unknown. METHODS: 10 patients (aged 39±16 years, mean±SD) underwent monitored adjustment of pump speed to determine minimum safe low speed and maximum safe high speed at rest. Patients were then randomized to these speed settings and underwent three 6-minute walk tests (6MWT) and symptom-limited cardiopulmonary stress tests (CPX) on separate days. RESULTS: Pump speed settings (low, normal and high) resulted in significantly different resting pump flows of 4.43±0.6, 5.03±0.94, and 5.72±1.2 l/min (P<.001). There was a significant enhancement of pump flows (greater at higher speed settings) with exercise (P<0.05). Increased pump speed was associated with a trend to increased 6MWT distance (P=.10); and CPX exercise time (p=.27). Maximum workload achieved and peak oxygen consumption were significantly different comparing low to high pump speed settings only (P<.05). N-terminal-pro-B-type natriuretic peptide release was significantly reduced at higher pump speed with exercise (P<.01). CONCLUSIONS: We have found that alteration of pump speed setting resulted in significant variation in estimated pump flow. The high-speed setting was associated with lower natriuretic hormone release consistent with lower myocardial wall stress. This did not, however, improve exercise tolerance.
No takes yet. Share an insight, caveat, or question.
Hayward et al. (2015) conducted an RCT in end-stage heart failure (n=10). Left ventricular assist device speed adjustment vs. low speed setting was evaluated on 6-minute walk test distance, cardiopulmonary stress test parameters, and NT-proBNP release (p=<.05 for max workload and peak oxygen consumption; <.01 for NT-proBNP). Adjusting LVAD to high-speed settings significantly reduced NT-proBNP release during exercise (P<.01) and improved maximum workload (P<.05), but did not significantly increase 6MWT distance (P=.10).