Key result
Cyclic alternating pattern phase A subtypes were accompanied by increased heart rate variability, with the largest increase in subtype A3 (HR increase 6.24 bpm) compared to A1 and A2 (P<0.001).
Observational (n=10)
No
p-value: p=<0.001
Cyclic alternating pattern phase A subtypes during sleep are associated with distinct, subtype-specific increases in heart rate, blood pressure, and autonomic nerve activity.
CAP A3-linked HR increases should not alter practice; hypothesis-generating for autonomic links between sleep microstructure and CV risk.
STUDY OBJECTIVES: Cyclic alternating pattern (CAP) is frequently followed by changes in heart rate (HR) and blood pressure (BP), but the sequential associations between CAP and autonomic nerve activity have not been studied. The study aimed to reveal the precise changes in heart rate variability (HRV) during phase A of the CAP cycle. DESIGN: Polysomnography was recorded according to the CAP Atlas (Terzano, 2002), and BP and electrocardiogram were simultaneously recorded. The complex demodulation method was used for analysis of HRV and evaluation of autonomic nerve activity. SETTING: Academic sleep laboratory. PARTICIPANTS: Ten healthy males. MEASUREMENTS AND RESULTS: The increase in HR (median [first quartile - third quartile]) for each subtype was as follows: A1, 0.64 (-0.30 to 1.69), A2, 1.44 (0.02 to 3.79), and A3, 6.24 (2.53 to 10.76) bpm (A1 vs. A2 P < 0.001, A1 vs. A3 P < 0.001, A2 vs. A3 P < 0.001). The increase in BP for each subtype was as follows: A1, 1.23 (-2.04 to 5.75), A2, 1.76 (-1.46 to 9.32), and A3, 12.51 (4.75 to 19.94) mm Hg (A1 vs. A2 P = 0.249, A1 vs. A3 P < 0.001, A2 vs. A3 P < 0.001). In all of phase A, the peak values for HR and BP appeared at 4.2 (3.5 to 5.4) and 8.4 (7.0 to 10.3) seconds, respectively, after the onset of phase A. The area under the curve for low-frequency and high-frequency amplitude significantly increased after the onset of CAP phase A (P < 0.001) and was higher in the order of subtype A3, A2, and A1 (P < 0.001). CONCLUSIONS: All phase A subtypes were accompanied with increased heart rate variability, and the largest heart rate variability was seen in subtype A3, while a tendency for less heart rate variability was seen in subtype A1.
No takes yet. Share an insight, caveat, or question.
Kondo et al. (2014) conducted an observational in Healthy (n=10). Cyclic alternating pattern (CAP) phase A vs. Subtypes A1, A2, and A3 was evaluated on Changes in heart rate variability (HRV), heart rate (HR), and blood pressure (BP) during phase A of the CAP cycle (p=<0.001). Cyclic alternating pattern phase A subtypes were accompanied by increased heart rate variability, with the largest increase in subtype A3 (HR increase 6.24 bpm) compared to A1 and A2 (P<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: