Key result
4D flow MRI viscous energy loss yields 0.83 AUC, outperforming echocardiography for predicting AS-related events.
Why the study?
To investigate whether 4D flow MRI viscous energy loss could determine aortic stenosis severity in accordance with transvalvular energy loss and aid surgical decision-making in asymptomatic severe AS.
Does viscous energy loss measured by 4D flow MRI predict aortic stenosis-related events better than conventional echocardiography in asymptomatic patients with severe aortic stenosis?
Observational (n=97)
No
Does viscous energy loss measured by 4D flow MRI predict aortic stenosis-related events better than conventional echocardiography in asymptomatic patients with severe aortic stenosis?
Viscous energy loss measured by 4D flow MRI provides superior risk stratification for clinical events compared to conventional echocardiography in asymptomatic patients with severe aortic stenosis.
Answers are grounded in this paper and cite their sources.
May aid risk stratification in asymptomatic severe AS; hypothesis-generating and requires prospective validation before adoption.
Purpose To investigate whether functional assessment of aberrant flow patterns by viscous energy loss (E′L) using four-dimensional (4D) flow MRI could determine aortic stenosis (AS) severity in accordance with transvalvular energy loss and aid in surgical decision-making in asymptomatic patients with severe AS. Materials and Methods In this prospective, single-center study, E′L was measured in the thoracic aorta of 74 consecutive asymptomatic patients with severe AS and preserved left ventricular ejection fraction who presented between January 2015 and December 2017, and 23 healthy volunteers using 4D flow MRI. Transvalvular energy loss was assessed based on the energy loss index (ELI) measured using Doppler echocardiography. The association between E′L and AS-related events including aortic valve replacement was evaluated by receiver operating characteristic curve analysis, Kaplan-Meier analysis, and multivariable Cox regression analysis. Results Among 74 asymptomatic patients with severe AS (mean age, 60 years ± 9 [SD]; 43 men; 56 with bicuspid aortic valve), 33 experienced AS-related events during a median follow-up of 42 months (IQR, 30–53 months). Altered flow patterns in severe AS resulted in a sevenfold increase in peak systolic E′L in the ascending aorta compared with controls (13.9 mW ± 3.4 vs 1.80 mW ± 0.44; P < .001). Peak systolic E′L in the ascending aorta was independently associated with the ELI (standardized β, −0.52; P < .001) and showed better discrimination for AS-related events (area under the curve, 0.83; 95% CI: 0.74, 0.93; P < .001) than conventional echocardiographic parameters. After adjustment for confounding variables, peak systolic E′L in the ascending aorta was associated with a significant increase in AS-related events (P < .001 for adjusted hazard ratio). Conclusion Changes in AS-mediated poststenotic three-dimensional outflow patterns can be quantified by 4D flow MRI-derived energetic markers to aid in the risk stratification and clinical management of asymptomatic patients with severe AS. Keywords: Aortic Stenosis, 4D Flow MRI, Flow Energetics, Vascular, Aorta, Aortic Valve, MR Angiography Supplemental material is available for this article.
No takes yet. Share an insight, caveat, or question.
Shan et al. (2022) conducted an observational in Asymptomatic severe aortic stenosis (n=97). 4D flow MRI-derived viscous energy loss (E′L) vs. Conventional echocardiographic parameters was evaluated on AS-related events including aortic valve replacement (AUC 0.83, 95% CI 0.74-0.93, p=<0.001). Peak systolic viscous energy loss measured by 4D flow MRI showed better discrimination for AS-related events than conventional echocardiography.