Key result
Training cardiologists on AI-derived ECG criteria for reduced LVEF is linked to ~11% higher accuracy.
Why the study?
The black box nature of artificial intelligence hinders the development of interpretable AI models applicable in clinical practice.
Does an explainable AI model improve the classification of reduced LVEF from 12-lead ECGs?
Observational (n=29,907)
Yes
Does an explainable AI model improve the classification of reduced LVEF from 12-lead ECGs?
An explainable AI model using six specific ECG findings can classify reduced LVEF, and its interpretation criteria can significantly improve cardiologists' diagnostic accuracy.
Answers are grounded in this paper and cite their sources.
May aid cardiologist ECG interpretation of reduced LVEF; hypothesis-generating and requires prospective validation before practice change.
Aims The black box nature of artificial intelligence (AI) hinders the development of interpretable AI models that are applicable in clinical practice. We aimed to develop an AI model for classifying patients of reduced left ventricular ejection fraction (LVEF) from 12-lead electrocardiograms (ECG) with the decision-interpretability. Methods and results We acquired paired ECG and echocardiography datasets from the central and co-operative institutions. For the central institution dataset, a random forest model was trained to identify patients with reduced LVEF among 29 907 ECGs. Shapley additive explanations were applied to 7196 ECGs. To extract the model’s decision criteria, the calculated Shapley additive explanations values were clustered for 192 non-paced rhythm patients in which reduced LVEF was predicted. Although the extracted criteria were different for each cluster, these criteria generally comprised a combination of six ECG findings: negative T-wave inversion in I/V5–6 leads, low voltage in I/II/V4–6 leads, Q wave in V3–6 leads, ventricular activation time prolongation in I/V5–6 leads, S-wave prolongation in V2–3 leads, and corrected QT interval prolongation. Similarly, for the co-operative institution dataset, the extracted criteria comprised a combination of the same six ECG findings. Furthermore, the accuracy of seven cardiologists’ ECG readings improved significantly after watching a video explaining the interpretation of these criteria (before, 62.9% ± 3.9% vs. after, 73.9% ± 2.4%; P = 0.02). Conclusion We visually interpreted the model’s decision criteria to evaluate its validity, thereby developing a model that provided the decision-interpretability required for clinical application.
No takes yet. Share an insight, caveat, or question.
Katsushika et al. (2023) conducted an observational in Reduced left ventricular ejection fraction (n=29,907). Explainable AI-enabled ECG analysis model vs. Cardiologists' ECG readings before explanation was evaluated on Accuracy of cardiologists' ECG readings (p=0.02). An explainable AI model identified six ECG criteria for reduced LVEF, and educating cardiologists on these criteria improved their diagnostic accuracy from 62.9% to 73.9%.
Synapse has enriched 10 related papers. Consider them for comparative context: