Key result
Automated blood pressure measurements in 4023 pregnant women established that values >130/80 mmHg and <90/50 mmHg represent the 95th and 5th centiles, respectively.
Why the study?
What are the reference ranges for automated blood pressure measurements throughout pregnancy in a large population?
Cross-Sectional (n=4,023)
No
What are the reference ranges for automated blood pressure measurements throughout pregnancy in a large population?
The study establishes new reference ranges for automated blood pressure in pregnancy, suggesting that the WHO definition of high diastolic BP (>90 mmHg) may be too conservative for detecting pre-eclampsia risk.
Answers are grounded in this paper and cite their sources.
Does not support revising pregnancy BP thresholds; extends centile data but leaves outcome impact open.
OBJECTIVE: To generate reliable new reference ranges for pregnancy blood pressure from a large population. DESIGN: A prospective cross sectional study. SETTING: Obstetric outpatient clinic, Zurich University Hospital. SAMPLE: Accurately dateable singleton pregnancies (Caucasian: n= 3234; Asian [predominantly from Sri Lanka, Thailand and the Philippines]: n= 577; Black n= 212). METHODS: Between January 1996 and February 2000 blood pressure was determined in 4023 pregnant women using an oscillometric automated device (Dinamap) according to British Hypertension Society recommendations. Women receiving antihypertensive medication were excluded. MAIN OUTCOME MEASURE: Blood pressure. RESULTS: Only the means of duplicate measures at the booking visit (5-42 weeks) were used in the analysis. Mean blood pressure decreased from early to mid pregnancy before increasing to levels 4 mmHg higher at term than in early pregnancy. Values >130/80 and <90/50 mmHg were above the 95th and below the 5th centiles, respectively. Parity, age and body mass index were significant determinants in Caucasians. Blood pressure was slightly lower in Asians and Blacks. CONCLUSIONS: The current World Health Organisation definition of high diastolic blood pressure (>or=90 mmHg on two occasions) reflects values >2 standard deviations from the mean. This may be too conservative as threshold for detecting women at risk of pre-eclampsia. Further studies are required to determine the prognostic implications of gestational values >or=95th centile (>or=130/80 mmHg) and <or=5th centile (<or=90/50 mmHg).
No takes yet. Share an insight, caveat, or question.
Ochsenbein‐Kölble et al. (2004) conducted a cross-sectional in Pregnancy (n=4,023). Automated blood pressure measurement was evaluated on Blood pressure. Automated blood pressure measurements in 4023 pregnant women established that values >130/80 mmHg and <90/50 mmHg represent the 95th and 5th centiles, respectively.
Synapse has enriched 10 related papers. Consider them for comparative context: