Answers are grounded in this paper and cite their sources.
BACKGROUND: Carotid body tumors (CBTs) depict the most common paraganglioma of the head and neck that can metastasize in up to 15% of cases. They develop either sporadically or hereditarily and may produce catecholamines ("functioning CBTs") resulting in associated symptoms like headache, palpitations or flush. Non-functioning CBTs usually present as slowly and often tender growing mass which may affect adjacent cranial nerves. CBTs can be visualized by ultrasound, CT, MRI or angiography. Pre-surgical interventional embolization, surgical resection and radiation therapy are therapeutical options. The aim of this retrospective single-center study is to assess the safe and real-time evaluation of CBTs by contrast-enhanced ultrasound (CEUS). METHODS: software was used for standardized perfusion quantification. RESULTS: CEUS allowed to detect all CBTs and visualize intratumoral microcirculation. Perfusion quantification was performed in 6/10 cases. CBTs showed significantly reduced peak-enhancement (PE), reduced wash-in perfusion index (WiPI) and significantly elevated time to peak (TTP) compared to common carotid arteries (CCA). CONCLUSIONS: CEUS is a useful and safe tool for identifying CBTs and evaluating intratumoral microperfusion at high spatial and temporal resolutions in real-time. In addition to conventional ultrasound, CT, MRI and digital substraction angiography (DSA), CEUS may be implemented in the future diagnostic work-up and follow-up of CBT patients.
No takes yet. Share an insight, caveat, or question.
Schwarze et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: