Key result
Serial 3-D IVUS evaluation showed that neointimal volume within coronary stents did not significantly change from 6 months (38.4 +/- 9.0 mm3) to over 1 year (33.8 +/- 10.3 mm3).
Why the study?
Does neointimal volume change between 6 months and over 1 year after coronary stenting in patients without restenosis at 6 months?
Observational (n=9)
Does neointimal volume change between 6 months and over 1 year after coronary stenting in patients without restenosis at 6 months?
In patients without angiographic restenosis at 6 months after coronary stenting, neointimal volume does not significantly increase over the subsequent year.
Neointimal stability after 6 months may reassure in non-restenotic stents; leaves open confirmation in larger prospective cohorts.
The long-term outcomes of coronary artery stenting have been determined by coronary angiography only with has the limitation of determining stent expansion and neointimal proliferation at long-term follow-up. Volumetric intravascular analysis has the potential to evaluate the morphology and distribution of neointima longitudinally after coronary artery stenting. We used three-dimensional intravascular ultrasound (3-D IVUS) to evaluate serial changes in stent and neointimal volumes for over 1-year in 9 patients who did not exhibit angiographic restenosis at 6-month follow-up. Volumetric analysis by a validated Netra 3-D IVUS system was performed pre- and post-intervention, at 6-month follow-up (FU1), and at over one-year follow-up (FU2). Lumen volume in the stented lesions increased significantly after intervention, and the increase persisted until FU2. There were no significant changes in stent volume between just after stent implantation and at FU2. Neointimal volume within the stents did not change from FUI to FU2 (FU1; 38.4 +/- 9.0 mm3 vs FU2; 33.8 +/- 10.3 mm3). In 33% (3/9) of all lesions, neointimal volume increased between from 6-months to over 1-year after stent implantation. Neointimal distribution after stenting seemed to be almost equal and unrelated to the plaque burden at pre-intervention. Neointimal volume within the stents did not increase and stent volume did not change over the 1st-year in patients who did not exhibit angiographic restenosis at 6-months.
No takes yet. Share an insight, caveat, or question.
Suzumura et al. (2002) conducted an observational in Coronary artery stenting without angiographic restenosis (n=9). Serial three-dimensional intravascular ultrasound (3-D IVUS) was evaluated on Serial changes in stent and neointimal volumes. Serial 3-D IVUS evaluation showed that neointimal volume within coronary stents did not significantly change from 6 months (38.4 +/- 9.0 mm3) to over 1 year (33.8 +/- 10.3 mm3).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: