Key result
An emulation approach predicted excitation behaviour with up to 96% accuracy, identifying slow recovery of excitability as a significant promoter of ventricular fibrillation risk.
Computational emulation identifies slow recovery of excitability as a key mechanism for increased dispersion of repolarization and ventricular fibrillation risk, explaining the pro-arrhythmic effects of class Ic anti-arrhythmics in the ventricles.
Slow recovery of excitability may promote ventricular fibrillation; computational emulation leaves open translation to class Ic safety in humans.
Purpose: Rotor stability and meandering are main mechanisms determining and sustaining cardiac fibrillation, with important implications for anti-arrhythmic drug development. However, little is yet known on how rotor dynamics are modulated by variability in cellular electrophysiology, particularly on kinetic properties of ion channel recovery. Methods: We propose a novel emulation approach, based on Gaussian process regression augmented with machine learning, for data enrichment, automatic detection, classification and analysis of re-entrant biomarkers in cardiac tissue. More than 5,000 monodomain simulations of long-lasting arrhythmic episodes with Fenton–Karma ionic dynamics, further enriched by emulation to 80 million electrophysiological scenarios, were conducted to investigate the role of variability in ion channel densities and kinetics in modulating rotor-driven arrhythmic behaviour. Results: Our methods predicted the class of excitation behaviour with classification accuracy up to 96\%, and emulation effectively predicted frequency, stability and spatial biomarkers of functional re-entry. We demonstrate that the excitation wavelength interpretation of re-entrant behaviour hides critical information about rotor persistence and devolution into fibrillation. In particular, whereas action potential duration directly modulates rotor frequency and meandering, critical windows of excitability are identified as the main determinants of breakup. Further novel electrophysiological insights of particular relevance for ventricular arrhythmias arise from our multivariate analysis, including the role of incomplete activation of slow inward currents in mediating tissue rate-dependence and dispersion of repolarisation, and the emergence of slow recovery of excitability as a significant promoter of this mechanism of dispersion and increased arrhythmic risk. Conclusions: Our results mechanistically explain pro-arrhythmic effects of class Ic anti-arrhythmics in the ventricles despite their established role in the pharmacological management of atrial fibrillation. This is mediated by their slow recovery of excitability mode of action, promoting incomplete activation of slow inward currents and therefore increased dispersion of repolarisation, given the given the larger influence of these currents in modulating the action potential in the ventricles compared to the atria. These results exemplify the potential of emulation techniques in elucidating novel mechanisms of arrhythmia and further application to cardiac electrophysiology.
No takes yet. Share an insight, caveat, or question.
Lawson et al. (2018) studied Ventricular Fibrillation. Emulation approach based on Gaussian process regression and machine learning was evaluated on Classification accuracy of excitation behaviour. An emulation approach predicted excitation behaviour with up to 96% accuracy, identifying slow recovery of excitability as a significant promoter of ventricular fibrillation risk.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: