Answers are grounded in this paper and cite their sources.
The aim of this work is to measure the hydrogen transport and solubility parameters in the commercial alumina. Measurements are conducted using a time‐dependent permeation method over the temperature range 1273–1673 K with hydrogen driving pressures in the range 10 4 –10 5 Pa (100–1000 mbar). A half‐power pressure dependence (diffusion‐limited permeation) of the permeation flux for alumina is observed. The Arrhenius expressions for the hydrogen permeability, diffusivity, and Sieverts' constant values obtained from a fitting to the whole temperature range are as follows: P =3.3·10 −10 exp(−97420/ RT ) mol·m −1 ·s −1 ·Pa −1/2 D =9.7·10 −8 exp(−79990/ RT ) m 2 ·s −1 K s =5.5·10 −3 exp(−22540/ RT ) mol·m −3 ·Pa −1/2
No takes yet. Share an insight, caveat, or question.
Serra et al. (2004) studied this question.