Addition of an input filter to a current-programmed converter can cause the controller to oscillate. Two instability mechanisms can typically occur: (1) the current programmed controller effective current feedback loop may become unstable, or (2) the controller effective input voltage feedforward loop, which becomes a positive feedback loop when an input filter is added, may oscillate. Three design criteria for preventing oscillations are derived and interpreted. When all three criteria are well satisfied, then the output voltage regulation loop gain is unchanged. Hence, input filters of current programmed converters can be designed in essentially the same manner as for duty-ratio programmed converters. Results are summarized in tabular form for the basic buck, boost, and buck-boost converters. Experimental measurements for a buck converter with different input filters support the theoretical predictions.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
No takes yet. Share an insight, caveat, or question.
Jang et al. (1992) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: