Key result
Miniature transoesophageal echocardiography using a 10 F intracardiac probe safely and successfully guided transseptal catheterization in 100% of patients without requiring sedation or anesthesia.
Why the study?
Does miniature transoesophageal echocardiography using a 10 F intracardiac probe (ICE-TEE) safely and effectively guide transseptal puncture during atrial fibrillation ablation without sedation?
Observational (n=79)
Does miniature transoesophageal echocardiography using a 10 F intracardiac probe (ICE-TEE) safely and effectively guide transseptal puncture during atrial fibrillation ablation without sedation?
ICE-TEE is a safe, well-tolerated, and effective method for guiding transseptal puncture during AF ablation without the need for sedation or general anesthesia.
Answers are grounded in this paper and cite their sources.
May support sedation-free transseptal guidance in AF ablation; hypothesis-generating and requires prospective validation.
AIMS: To assess the usefulness of miniature transoesophageal echocardiography using a 10 F intracardiac probe (ICE-TEE) for transseptal catheterization during atrial fibrillation (AF) ablation. METHODS AND RESULTS: Intracardiac echocardiography probe was used transoesophageally in 79 consecutive patients (56 ± 11 years, 73% male) referred for AF ablation (60% paroxysmal and 38% persistent) to guide transseptal puncture. Transseptal catheterization monitored by ICE-TEE was well tolerated and successfully performed in all patients without any sedation. No mechanical oesophageal complication was noted. Moreover, the mean duration between ICE-TEE probe insertion and successful transseptal puncture was 4.5 min and the mean time of ICE-TEE was 10 min. Finally, no tamponade occurred during the AF ablation procedure. CONCLUSION: Intracardiac echocardiography-TEE is safe and well tolerated for the guidance of transseptal catheterization during AF ablation. Moreover, this technique was performed without requiring any anaesthesia.
No takes yet. Share an insight, caveat, or question.
Mitchell-Heggs et al. (2010) conducted an observational in Atrial fibrillation (n=79). Miniature transoesophageal echocardiography using a 10 F intracardiac probe (ICE-TEE) was evaluated on Successful transseptal catheterization and safety. Miniature transoesophageal echocardiography using a 10 F intracardiac probe safely and successfully guided transseptal catheterization in 100% of patients without requiring sedation or anesthesia.
Synapse has enriched 10 related papers. Consider them for comparative context: