Key result
Varying pacing cycle length increases instability markers several-fold, predicting conduction block sites.
Why the study?
Evaluating cardiac conduction velocity and block is essential because slow conduction and block initiate reentry, but assessing conduction safety in experimental and clinical settings remains elusive.
Does pacing with stochastic or alternating variations of cycle length predict sites of conduction block in neonatal murine cardiomyocytes and computer simulations?
Does pacing with stochastic or alternating variations of cycle length predict sites of conduction block in neonatal murine cardiomyocytes and computer simulations?
Introducing beat-to-beat variations in pacing cycle length reveals local conduction variability that predicts sites of conduction block, which may help identify ablation targets in clinical electrophysiology.
Hypothesis-generating for mapping ablation targets via variable pacing; leaves open translation from murine models to clinical use.
Reentry, the most common cause of severe arrhythmias, is initiated by slow conduction and conduction block. Hence, evaluating conduction velocity and conduction block is of primary importance. However, the assessment of cardiac conduction safety in experimental and clinical settings remains elusive. To identify markers of conduction instability that can be determined experimentally, we developed an approach based on new pacing paradigms. Conduction across a cardiac tissue expansion was assessed in computer simulations and in experiments using cultures of neonatal murine cardiomyocytes on microelectrode arrays. Simulated and in vitro tissues were paced at a progressively increasing rate, with stochastic or alternating variations of cycle length, until conduction block occurred. Increasing pacing rate led to conduction block near the expansion. When stochastic or alternating variations were introduced into the pacing protocol, the standard deviation and the amplitude of alternating variations of local conduction times emerged as markers of unstable conduction prone to block. In both simulations and experiments, conduction delays were prolonged at the expansion but increased only slightly during the pacing protocol. In contrast, these markers of instability increased several-fold, early before block occurrence. The first and second moments of these two metrics provided an estimation of the site of block and the accuracy of this estimation. Therefore, when beat-to-beat variations of pacing cycle length are introduced into a pacing protocol, the local variability of conduction permits to predict sites of block. Our pacing paradigms may have translational applications in clinical cardiac electrophysiology, particularly in identifying ablation targets during mapping procedures.
No takes yet. Share an insight, caveat, or question.
Waard et al. (2024) studied Cardiac conduction instability / Arrhythmias. Stochastic or alternating variations of pacing cycle length was evaluated on Markers of unstable conduction prone to block (standard deviation and amplitude of alternating variations of local conduction times). Introducing stochastic or alternating variations of pacing cycle length into a pacing protocol increased markers of instability several-fold, permitting the prediction of sites of conduction block.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: