Key result
COX-MAZE IV plus valve surgery restores sinus rhythm in ~78% of AF patients immediately post-op.
Why the study?
Atrial fibrillation is a major cause of stroke, heart failure, and sudden death, and the Maze procedure using radiofrequency devices is often combined with valvular surgery to treat it.
Does the Cox-Maze IV procedure combined with valve surgery improve sinus rhythm recovery in patients with atrial fibrillation and valve disease?
Cross-Sectional (n=40)
No
Does the Cox-Maze IV procedure combined with valve surgery improve sinus rhythm recovery in patients with atrial fibrillation and valve disease?
The Cox-Maze IV procedure using radiofrequency energy combined with mitral and other valve surgeries is safe and effective, achieving a 77.5% early sinus rhythm recovery rate.
Answers are grounded in this paper and cite their sources.
Early sinus rhythm restoration seen with Cox-Maze IV during valve surgery; hypothesis-generating and needs randomized confirmation.
Introduction: Atrial fibrillation is a major cause of stroke, heart failure, and sudden death and is often associated with valve disease. The Maze procedure using the unipolar and bipolar radiofrequency devices is often combined with valvular surgery, especially mitral valve, to treat atrial fibrillation. Method: Cross-sectional descriptive study; 40 patientsss were treated for atrial fibrillation by COX-MAZE procedure combined with heart valve surgery in 2020-2021 at Cardiovascular Center- E Hospital. Result: In 40 patients, 23 males (57.5%), 17 females (42.5%), mean age 53.6 ± 8.3 (36-68) years. Mean time to dêtct atrial fibrillation 3.27 (1-9) years. 05 cases (12.5%) were preopration stroke history. Mean left atrial diameter before surgery 49.2 ± 10.1 (21-70) mm, thrombus in left atrial appendage was 8 cases (20%). All patients had mitral valve disease, accompanied by aortic valve disease 4 cases (10%) and tricuspid valve regurgitation 13 cases (32.5%). 100% of patients underwent COX-MAZE procedure. The rates of free from AF and sinus recovery after surgery 31 cases (77.5%). 02 patients (5%) sinus node dysfunction and 04 patients (10%) atrioventricular block I-II degree but they did not require temporary pacemaker placement, and recovered in 1-3 weeks. Conclusion: The Maze procedure by unipolar devices alone and combination with bipolar devices are effective and safe in patient atrial fibrillation combined with valvular surgery, especially mitral valve surgery.
No takes yet. Share an insight, caveat, or question.
Thuy et al. (2022) conducted a cross-sectional in Atrial fibrillation combined with heart valve disease (n=40). COX-MAZE IV procedure combined with heart valve surgery was evaluated on Free from atrial fibrillation and sinus rhythm recovery after surgery. The COX-MAZE IV procedure combined with heart valve surgery successfully restored sinus rhythm in 77.5% of patients with atrial fibrillation immediately after surgery.
Synapse has enriched 10 related papers. Consider them for comparative context: