Answers are grounded in this paper and cite their sources.
Interferometric gravitational wave detectors require a large degree of vibration isolation. For this purpose, a multilayer stack constructed of rubber and metal blocks is suitable, because it provides isolation in all degrees of freedom at once. In TAMA300, a 300 m interferometer in Japan, long-term dimensional stability and compatibility with an ultrahigh vacuum environment of about 10−6 Pa are also required. To keep the interferometer at its operating point despite ground strain and thermal drift of the isolation system, a thermal actuator was introduced. To prevent the high outgassing rate of the rubber from spoiling the vacuum, the rubber blocks were enclosed by gas-tight bellows. Using these techniques, we have successfully developed a three-layer stack which has a vibration isolation ratio of more than 103 at 300 Hz with control of drift and enough vacuum compatibility.
No takes yet. Share an insight, caveat, or question.
Takahashi et al. (2002) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: