Full-order continuous-time average modeling and dynamic analysis of bidirectional dc-dc dual active bridge (DAB) converters are studied. The transformer current in DAB converter is purely ac, making continuous-time modeling difficult. The proposed full-order continuous-time average model uses the dc terms and first order terms of transformer current and capacitor voltage as state variables, resulting in a third-order model, if capacitor equivalent series resistance (ESR) is not considered, and a sixth-order model if ESR is considered. A control-to-output-voltage transfer function is derived for DAB converters. Experimental results confirm that the proposed model correctly predicts the small-signal frequency response and an even more accurate prediction can be obtained if capacitor ESR is taken into account.
No takes yet. Share an insight, caveat, or question.
Qin et al. (2011) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: