Key result
1-min smartphone PPG for ultra-short-term HRV demonstrates high feasibility with ~95% patient compliance.
Why the study?
Autonomic nervous system activation plays an important role in AF pathophysiology and can be determined via HRV, but the feasibility of using PPG recordings for ultra-short-term HRV assessment needed evaluation.
Does a photoplethysmography-based smartphone application feasibly measure ultra-short-term heart rate variability in patients managed for atrial fibrillation?
Observational (n=855)
Does a photoplethysmography-based smartphone application feasibly measure ultra-short-term heart rate variability in patients managed for atrial fibrillation?
Ultra-short-term heart rate variability can be feasibly and consistently measured using a 1-minute PPG-based smartphone application with high patient compliance.
Supports smartphone PPG for remote HRV monitoring in AF; leaves open validation and outcome impact.
Aims Autonomic nervous system activation plays an important role in the pathophysiology of atrial fibrillation (AF). It can be determined using heart rate variability (HRV). We aimed to evaluate the feasibility of using photoplethysmography (PPG) recordings for the assessment of the ultra-short-term HRV. Methods and results TeleCheck-AF is a structured mobile health approach, comprising the on-demand use of a PPG-based smartphone application prior to a scheduled teleconsultation to ensure comprehensive remote AF management. Participants with at least one PPG recording in sinus rhythm were included to assess resting heart rate, root mean square of successive differences (RMSSD), patient compliance and data consistency. In total, 855 patients [39.4% women] with 13 465 recordings were included. Patient compliance was 95.2% (IQR 76.2–114.3%). Median heart rate per patient was 66.5 (IQR 60.0–74.0) b.p.m., median RMSSD per patient was 40 (IQR 33–50) ms and median recording consistency was ±5.2 (IQR 3.8–7.0) b.p.m. and ±14.8 (IQR 9.3–21.1) ms, respectively. RMSSD was lower in men than women, in patients with CHA2D2-VA-Score 0, with a history of AF, and following ablation of AF. Older age and lower body mass index were associated with higher RMSSD. Conclusion The ultra-short-term HRV can be determined in 1-min PPG recordings with high user compliance and high inter-recording consistency within a structured mobile health AF management approach. The strategy used in this study may also be feasible for the management of other conditions in which the HRV plays a role for diagnostics and therapy.
No takes yet. Share an insight, caveat, or question.
Hillmann et al. (2025) conducted an observational in Atrial fibrillation (n=855). Photoplethysmography (PPG)-based smartphone application was evaluated on Patient compliance and data consistency. Ultra-short-term heart rate variability assessment using 1-min PPG smartphone recordings demonstrated high feasibility, with a patient compliance rate of 95.2%.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: