Key result
Ultrasound backscatter reduction at 20° accurately distinguishes hypertonic from normal muscles with ~0.89 peak AUC.
Why the study?
The study was conducted to investigate the feasibility of ultrasound backscatter parameters in assessing upper trapezius muscle hypertonicity.
Do ultrasound backscatter parameters accurately assess upper trapezius muscle hypertonicity in adults?
Observational (n=125)
Do ultrasound backscatter parameters accurately assess upper trapezius muscle hypertonicity in adults?
Ultrasound backscatter reduction rate at 20° beam steering can reliably distinguish hypertonic from normal upper trapezius muscles in young and middle-aged adults.
Answers are grounded in this paper and cite their sources.
Ultrasound backscatter reduction rate at 20° may aid noninvasive trapezius hypertonicity assessment in younger adults; leaves open prospective validation across ages.
Objectives To investigate the feasibility of ultrasound backscatter parameters in assessing upper trapezius muscle (UTM) hypertonicity. Methods We prospectively measured pixel intensity on B-mode ultrasound images of UTM and adjacent subcutaneous tissue (SUBC) using Image J histogram, and calculated backscatter reduction rate and anisotropy following beam steering at 5°, 10°, 15°, and 20° from 0°. We analyzed differences in backscatter parameters of UTM and SUBC between three age groups using one-way analysis of variance (ANOVA), between normal and hypertonic UTMs using paired t-test, diagnostic performances of backscatter parameters for determining ≥ mild hypertonic UTM using area under receiver operating characteristic curve (AUC), and inter- and intra-observer reliability in measuring pixel intensity using intraclass correlation coefficient (ICC) and Blant-Altman analysis. Results We recruited 125 adult subjects (39 with normal UTM, 86 with hypertonic UTM) in three age groups (young age: 18-44y; middle age: 45-64y; old age: ≥65y). Differences in backscatter parameters between normal and hypertonic UTM were significant in young and middle-aged groups (p< 0.01) but not in old-aged group ( p >0.05). AUC of muscle backscatter reduction rate at beam steering 20° for determining ≥ mild hypertonicity was 0.89, 0.80, and 0.64 in young, middle-aged, and old-aged participants, respectively. ICCs of observer reliability for measuring pixel intensity were > 0.80. Conclusions The muscle backscatter reduction rate at beam steering 20° can distinguish hypertonic muscles from normal muscles in young and middle-aged with good intra- and inter-operator reliability. Muscle backscatter reduction rate in adults decreases with aging and the occurrence of hypertonicity.
No takes yet. Share an insight, caveat, or question.
Gao et al. (2026) conducted an observational in Upper trapezius muscle hypertonicity (n=125). Ultrasound backscatter parameters vs. Normal upper trapezius muscle was evaluated on Diagnostic performance for determining ≥ mild hypertonic upper trapezius muscle (AUC 0.89 (young), 0.80 (middle-aged), p=<0.01). Ultrasound muscle backscatter reduction rate at 20° beam steering accurately distinguished hypertonic from normal muscles in young (AUC 0.89) and middle-aged (AUC 0.80) adults (p<0.01).