Key result
Ultrasound blood speckle tracking accurately maps vector flow across ≥80% of lumen area in abdominal aortic aneurysms.
Why the study?
The impact of clutter filtering and the feasibility of ultrasound blood speckle tracking to evaluate flow patterns in abdominal aortic aneurysms were not established.
Does ultrasound blood speckle tracking improve flow pattern evaluation in patients with abdominal aortic aneurysms?
Observational (n=13)
No
Does ultrasound blood speckle tracking improve flow pattern evaluation in patients with abdominal aortic aneurysms?
Ultrasound blood speckle tracking is feasible for quantifying systolic, but not diastolic, blood flow velocities in abdominal aortic aneurysms.
Supports systolic flow assessment in abdominal aortic aneurysms; leaves open diastolic utility and clinical adoption pending larger studies.
Objective Test the impact of clutter filtering and feasibility of ultrasound blood speckle tracking (BST) to evaluate flow patterns in abdominal aortic aneurysms. Methods Data were acquired for 7 patients diagnosed with an abdominal aortic aneurysm with minor intraluminal thrombus (ILT) volume, and 6 patients having substantial ILT volume, of which 10 patients were included in the assessment. A multi-observer assessment was done to tune and compare the performance of clutter filtering based on singular value decomposition (SVD) and polynomial regression, prior to BST. The quality of the resulting vector flow images was assessed in a second multi-observer assessment. Results After selecting a suitable filter threshold for each patient recording, only two out of 10 measurements had remaining clutter in the spectrograms during systole, and in one case during diastole. During systole, for 8 out of 10 patients 80% of the lumen area or more was deemed to have physiologically correct vector flow imaging (VFI) estimates. During diastole, this was only the case for 2 patients. For 4 patients, this percentage was lower than 50% during diastole. Conclusion During systole, BST can be applied to get accurate VFI results in the abdominal aortic aneurysm. Quantifying the lower velocity flow during diastole was less successful.
No takes yet. Share an insight, caveat, or question.
Løvstakken et al. (2026) conducted an observational in Abdominal aortic aneurysm (n=13). Ultrasound blood speckle tracking (BST) was evaluated on Physiologically correct vector flow imaging estimates in ≥80% of the lumen area during systole. During systole, ultrasound blood speckle tracking provided physiologically correct vector flow imaging estimates in 80% or more of the lumen area for 8 out of 10 assessed patients with abdominal aortic aneurysms.