Key result

4D flow MRI revealed that the true lumen had a significantly smaller mean area (192.73 vs 432.46 mm2) and higher average through-plane velocity compared to the false lumen in aortic dissection.

Why the study?

Can 4D flow MRI quantitatively assess hemodynamic differences between the true and false lumens in patients with aortic dissection?

Population

16 patients with sub-acute aortic dissection, mean age 51.19 years, without cardiac, hepatic, or renal…

Design

Cohort

Authors

DLDongting LiuQingdao UniversityZFZhanming FanCapital Medical UniversityYLYu LiUniversity of Nebraska Medical Center

Discussion

Loading...

Member takes

Overview

May support 4D flow MRI for lumen-specific hemodynamics in aortic dissection; hypothesis-generating, needs prospective validation.

Study Design

Type

Observational (n=16)

Multicenter

No

Structured PICO

Can 4D flow MRI quantitatively assess hemodynamic differences between the true and false lumens in patients with aortic dissection?

P
Population
16 patients (1 female, 15 males) with sub-acute aortic dissection (1 Stanford A, 15 Stanford B), mean age 51.19 years, without cardiac, hepatic, or renal function impairments.
I
Intervention
4D flow magnetic resonance imaging (MRI) and thoracic and abdominal computed tomography (CT) angiography
O
Outcome
Hemodynamic characteristics (velocity, flow, area, regurgitant fraction) of the true lumen (TL) and false lumen (FL) at four abdominal aortic levelssurrogate

Main Result

Absolute Event Rate: 192.73% vs 432.46%

p-value: p=<0.0001

4D flow MRI enables detailed quantitative assessment of complex hemodynamic alterations in the true and false lumens of patients with aortic dissection.

Limitations

  • Small number of participants and single-center experience
  • Low signal in the false lumen restricted analysis of flow features
  • Lack of a medically treated control group
  • Lack of longitudinal follow-up
  • Small sample size
  • Single-center experience
  • Low signal in the false lumen restricted flow feature analysis

Cite This Study

Liu et al. (2018) conducted an observational in Aortic Dissection (n=16). True lumen (4D flow MRI) vs. False lumen was evaluated on Mean area across all levels (mm2) (p=<0.0001). 4D flow MRI revealed that the true lumen had a significantly smaller mean area (192.73 vs 432.46 mm2) and higher average through-plane velocity compared to the false lumen in aortic dissection.

synapsesocial.com/papers/6a1562ff79ff98d0de4e8dd1https://doi.org/10.1038/s41598-018-27249-9
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Evaluation of Flow Volume and Flow Patterns in the Patent False Lumen of Chronic Aortic Dissections Using Velocity-Encoded Cine Magnetic Resonance Imaging2000 · 25 citations
  2. 2Comparison of flow patterns in ascending aortic aneurysms and volunteers using four‐dimensional magnetic resonance velocity mapping2007 · 237 citations
  3. 3Magnetic resonance velocity mapping1990 · 35 citations
  4. 4Cineangiography of the heart in a single breath hold with a segmented turboFLASH sequence.1991 · 383 citations
  5. 5Growth Rate of Aortic Diameter in Patients With Type B Aortic Dissection During the Chronic Phase2004 · 271 citations