Key result
Multi-velocity encoding 4D-flow MRI revealed reduced blood flow velocity and flow rate in the true lumen of CDTAD patients compared with normal aortas of healthy participants.
Why the study?
Does multi-VENC 4D-flow MRI enable detailed assessment of blood flow patterns in patients with chronic descending thoracic aortic dissection compared to healthy volunteers?
Observational (n=19)
Does multi-VENC 4D-flow MRI enable detailed assessment of blood flow patterns in patients with chronic descending thoracic aortic dissection compared to healthy volunteers?
Answers are grounded in this paper and cite their sources.
Multi-VENC 4D-flow MRI can quantify complex flow dynamics, such as reduced flow velocity and increased flow reversal in the false lumen, in patients with chronic aortic dissection.
BACKGROUND: Chronic descending thoracic aortic dissection (CDTAD) following surgical repair of ascending aortic dissection requires long-term imaging surveillance. We investigated four-dimensional (4D)-flow magnetic resonance imaging (MRI) with a novel multi-velocity encoding (multi-VENC) technique as an emerging clinical method enabling the dynamic quantification of blood volume and velocity throughout the cardiac cycle. METHODS: Patients with CDTAD (n = 10; mean age, 55.1 years; standard deviation (SD) 10.8) and healthy volunteers (n = 9; mean age, 37.1 years; SD 11.4; p < 0.01) underwent 3T MRI, and standard views and 4D-flow data were obtained. Flow measurements were made in selected regions of interest within the ascending and descending thoracic aorta. RESULTS: ) was lower in the FL than in the TL (p < 0.05), and both rates were lower than that of control aortas (p < 0.05). Blood flow reversal was higher in the FL than in the TL throughout the descending aorta in CDTAD patients (p < 0.05). A derived pulsatility index was elevated in the TL compared with that in the FL in CDTAD patients. Generated pathline images demonstrated flow patterns in detail, including sites of communication between the true and FL. CONCLUSIONS: 4D-flow MRI revealed FL blood flow and reduced blood flow velocity and flow rate in the TL of CDTAD patients compared with normal aortas of healthy participants. Thus, multi-VENC 4D-flow MRI could serve as an adjunct in the long-term assessment of CDTAD following surgical repair of ascending aortic dissection.
No takes yet. Share an insight, caveat, or question.
Sherrah et al. (2017) conducted an observational in Chronic descending thoracic aortic dissection (n=19). Multi-velocity encoding 4D-flow MRI vs. Healthy volunteers was evaluated on Blood flow velocity and flow rate (p=<0.05). Multi-velocity encoding 4D-flow MRI revealed reduced blood flow velocity and flow rate in the true lumen of CDTAD patients compared with normal aortas of healthy participants.
Synapse has enriched 10 related papers. Consider them for comparative context: