Key result
Electroconvulsive therapy proves safe in CIED patients with zero serious adverse effects requiring cessation.
Why the study?
The authors sought to report a case and systematically review published literature on the use of electroconvulsive therapy in patients with cardiac implantable electronic devices for treating major psychiatric disorders.
Is electroconvulsive therapy safe in patients with cardiac implantable electronic devices?
Systematic Review (n=76)
Is electroconvulsive therapy safe in patients with cardiac implantable electronic devices?
Electroconvulsive therapy appears safe for patients with cardiac implantable electronic devices, with no reported serious adverse effects requiring treatment cessation.
Objective The aims of the study were to report the case of a 54-year-old man with recurrent depressive disorder with multiple medical comorbidities having a dual-chamber pacemaker, treated successfully with 11 sessions of electroconvulsive therapy, and to conduct a systematic review of published cases documenting the use of electroconvulsive therapy (ECT) in patients with cardiac implantable electronic devices (CIEDs) for treating major psychiatric disorders. Methods We searched electronic databases (MEDLINE, PubMed, Google Scholar, Embase, Cochrane Library, PsycINFO, and Crossref) and included studies reporting on the use of electroconvulsive therapy in patients with CIEDs. Results Thirty-five publications across 53 years (1967–2021) reported on 76 patients (including current report) who received a pooled total of 979 modified ECT sessions. The most common adverse events were premature ventricular contraction and hypertension. There have been no reports of serious adverse effects that necessitated the cessation of ECT. Conclusions Electroconvulsive therapy is a safe and efficacious treatment for major psychiatric disorders, and the presence of CIEDs should not delay or deter the use of ECT in these patients.
No takes yet. Share an insight, caveat, or question.
Purohith et al. (2022) conducted a systematic review in Major psychiatric disorders with co-morbid cardiac implantable electronic devices (CIEDs) (n=76). Electroconvulsive therapy (ECT) was evaluated on Adverse events during or immediately after ECT.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: