Key result
Early ICD discharge linked to ~2-fold higher anxiety scores and worse quality of life.
Why the study?
The study was conducted to assess the impact of cardioverter-defibrillator interventions on patients' psychosocial functioning and concerns related to ICD.
Does experiencing an ICD discharge worsen psychosocial functioning and anxiety in patients with an implanted cardioverter-defibrillator?
Observational (n=158)
No
Does experiencing an ICD discharge worsen psychosocial functioning and anxiety in patients with an implanted cardioverter-defibrillator?
Absolute Event Rate: 8.21% vs 3.79%
p-value: p=<0.001
ICD discharges in the first six months post-implantation are associated with significantly worse quality of life, lower disease acceptance, and higher rates of anxiety, depression, and insomnia.
Early ICD discharges were associated with higher anxiety and worse QoL; leaves open causal effects and need for prospective trials.
Background and objectives: The aim of the study was to assess the impact of cardioverter-defibrillator interventions on the psychosocial functioning of a patient and the occurrence of concerns related to ICD. Materials and Methods: The conducted study was a prospective and observational study that included 158 patients. The study was conducted in two stages: I before ICD implantation and II a follow-up visit six months after the ICD implantation. Standardized questionnaires were used in both stages. Results: In the first six months, a cardioverter-defibrillator discharge occurred in 28 participants, which constituted 17.72% of the study group. The number of ICD discharges positively correlated to insomnia, symptoms of anxiety, symptoms of depression, more discharges, more severe insomnia, anxiety and depression. There was also a negative correlation between the number of discharges and the degree of disease acceptance and in the quality of life domains: somatic, mental, social and environmental. The more discharges, the worse the disease acceptance and assessment of the quality of life. Conclusions: Individuals who experienced discharges assessed their quality of life as worse in all aspects (perception of the quality of life, own health, physical, mental, social and environmental domains), experienced anxiety and depressive disorders more often, were characterized by a worse functioning in a chronic disease, experienced insomnia more often and reported more concerns related to ICD implantation.
No takes yet. Share an insight, caveat, or question.
Karczewska et al. (2021) conducted an observational in Implantable cardioverter-defibrillator (ICD) recipients (n=158). Cardioverter-defibrillator discharge vs. No cardioverter-defibrillator discharge was evaluated on Anxiety severity (HADS score) (p=<0.001). Patients experiencing an implantable cardioverter-defibrillator discharge within 6 months of implantation had significantly higher anxiety (HADS score 8.21 vs 3.79) and worse quality of life compared to those without discharges.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: