Key result
4D-flow MRI parameters show potential for quantifying early left ventricular diastolic dysfunction.
Why the study?
4D-flow MRI is increasingly recognized for detecting abnormal flow behaviour during early left ventricular dysfunction, but its clinical applicability needed systematic evaluation.
Does 4D-flow MRI provide clinically applicable parameters for the quantification of left ventricular function?
Systematic Review (n=1,070)
Does 4D-flow MRI provide clinically applicable parameters for the quantification of left ventricular function?
4D-flow MRI shows promise for detecting early left ventricular dysfunction through novel flow parameters, but requires larger-scale investigations and standardization before broader clinical application.
Answers are grounded in this paper and cite their sources.
4D-flow MRI parameters may aid early diastolic dysfunction detection; leaves open routine clinical use pending standardization and larger validation studies.
There is increasing recognition of the value of four-dimensional flow cardiovascular magnetic resonance (4D-flow MRI) as a potential means to detect and measure abnormal flow behaviour that occurs during early left ventricular (LV) dysfunction. We performed a systematic review of current literature on the role of 4D-flow MRI-derived flow parameters in quantification of LV function with a focus on potential clinical applicability. A comprehensive literature search was performed in March 2022 on available databases. A total of 1186 articles were identified, and 30 articles were included in the final analysis. All the included studies were ranked as "highly clinically applicable". There was considerable variability in the reporting of methodologies and analyses. All the studies were small-scale feasibility or pilot studies investigating a diverse range of flow parameters. The most common primary topics of investigation were energy-related flow parameters, flow components and vortex analysis which demonstrated potentials for quantifying early diastolic dysfunction, whilst other parameters including haemodynamic forces, residence time distribution and turbulent kinetic energy remain in need of further evaluation. Systematic quantitative comparison of study findings was not possible due to this heterogeneity, therefore limiting the collective power of the studies in evaluating clinical applicability of the flow parameters. To achieve broader clinical application of 4D-flow MRI, larger scale investigations are required, together with standardisation of methodologies and analytical approach.
No takes yet. Share an insight, caveat, or question.
Qin et al. (2022) conducted a systematic review in Left ventricular dysfunction (n=1,070). Four-dimensional flow cardiovascular magnetic resonance (4D-flow MRI) was evaluated on Clinical applicability of 4D-flow MRI-derived flow parameters in quantification of LV function. 4D-flow MRI-derived parameters, particularly energy-related flow, flow components, and vortex analysis, demonstrate potential for quantifying early diastolic dysfunction.
Synapse has enriched 10 related papers. Consider them for comparative context: