Key result
4D flow CMR reliably quantifies LV kinetic energy with ~6% variability across studies.
Why the study?
There is emerging evidence supporting the potential clinical value of LV intracavity blood flow kinetic energy assessment using 4D flow CMR, but studies on its quantification methods and clinical significance needed summarization.
Does 4D flow CMR assessment of LV blood flow kinetic energy provide clinically relevant and reproducible hemodynamic information in patients with cardiovascular diseases?
Systematic Review (n=16)
Does 4D flow CMR assessment of LV blood flow kinetic energy provide clinically relevant and reproducible hemodynamic information in patients with cardiovascular diseases?
4D flow CMR assessment of LV blood flow kinetic energy is a highly reproducible, emerging imaging biomarker with potential clinical utility for evaluating LV hemodynamics in various cardiovascular diseases.
Answers are grounded in this paper and cite their sources.
High reproducibility may support clinical adoption of 4D flow CMR for LV hemodynamics; extends evidence for diastolic function assessment.
Background: There is an emerging body of evidence that supports the potential clinical value of left ventricular (LV) intracavity blood flow kinetic energy (KE) assessment using four-dimensional flow cardiovascular magnetic resonance imaging (4D flow CMR). The aim of this systematic review is to summarize studies evaluating LV intracavity blood flow KE quantification methods and its potential clinical significance. Methods: A systematic review search was carried out on Medline, Pubmed, EMBASE and CINAHL. Results: Of the 677 articles screened, 16 studies met eligibility. These included six (37%) studies on LV diastolic function, another six (37%) studies on heart failure or cardiomyopathies, three (19%) studies on ischemic heart disease or myocardial infarction and finally, one (6%) study on valvular heart disease, namely, mitral regurgitation. One of the main strengths identified by these studies is high reproducibility of LV blood flow KE hemodynamic assessment (mean coefficient of variability = 6 ± 2%) for the evaluation of LV diastolic function. Conclusions: The evidence gathered in this systematic review suggests that LV blood flow KE has great promise for LV hemodynamic assessment. Studies showed increased diagnostic confidence at no cost of additional time. Results were highly reproducible with low intraobserver variability.
No takes yet. Share an insight, caveat, or question.
Kaur et al. (2020) conducted a systematic review in Cardiovascular diseases (LV diastolic function, heart failure, ischemic heart disease, valvular heart disease) (n=16). 4D flow cardiovascular magnetic resonance (CMR) for LV blood flow kinetic energy assessment was evaluated on Reproducibility of LV blood flow kinetic energy hemodynamic assessment. Left ventricular blood flow kinetic energy assessment by 4D flow CMR is a highly reproducible method that shows great promise for evaluating LV hemodynamics.