Key result
Novel automated system improves AF detection over conventional metrics, reaching an MCC of 0.59.
Why the study?
Standard ECGs are typically performed infrequently and require expert interpretation, making accessible, continuous cardiac monitoring via pulse interval measurements desirable.
Does a combined HRV metric algorithm (Lv and Lg) improve the detection of AF, PVC, and PAC compared to conventional metrics in outpatients?
Observational (n=1,017)
No
Does a combined HRV metric algorithm (Lv and Lg) improve the detection of AF, PVC, and PAC compared to conventional metrics in outpatients?
Answers are grounded in this paper and cite their sources.
A novel algorithm combining local and global heart rate variability metrics can accurately detect atrial fibrillation and premature contractions using as little as 1 minute of pulse interval data.
Cardiac disorders are common conditions associated with a high mortality rate. Due to their potential for causing serious symptoms, it is desirable to constantly monitor cardiac status using an accessible device such as a smartwatch. While electrocardiograms (ECGs) can make the detailed diagnosis of cardiac disorders, the examination is typically performed only once a year for each individual during health checkups, and it requires expert medical practitioners to make comprehensive judgments. Here we describe a newly developed automated system for alerting individuals about cardiac disorders solely based on pulse interval measurements. For this purpose, we examined two metrics of heart rate variability (HRV) and analyzed 1-day ECG recordings of more than 1,000 subjects in total. We found that a newly introduced metric of local variation was more efficient than conventional HRV metrics for detecting premature contraction, and furthermore, that a suitable combination of the old and new metrics resulted in much superior detectability particularly for atrial fibrillation, which requires more attention. Even with a 1-minute recording of pulse intervals, our new detection system had a diagnostic performance even better than that of the conventional analysis method applied to a 1-day recording.
No takes yet. Share an insight, caveat, or question.
Shinomoto et al. (2022) conducted an observational in Cardiac disorders (Atrial Fibrillation, Premature Ventricular Contraction, Premature Atrial Contraction) (n=1,017). Combination of local variation (Lv) and local-global variation ratio (Lg) metrics vs. Conventional coefficient of variation (Cv) metric was evaluated on Matthews correlation coefficient (MCC) for detecting atrial fibrillation. A novel automated detection system combining local variation and local-global variation ratio metrics improved the detection of atrial fibrillation compared to conventional metrics, achieving a Matthews correlation coefficient of 0.59 versus 0.33.
Synapse has enriched 10 related papers. Consider them for comparative context: