Answers are grounded in this paper and cite their sources.
Demonstrates direct quantification of mRNA in lipid nanoparticles, highlighting improved manufacturing efficiency.
Deep-UV resonance Raman spectroscopy (DUV-RRS) enables rapid, label-free quantification of mRNA directly in intact lipid nanoparticles. Without deformulation, seconds-scale acquisitions isolate adenine and guanine signatures with minimal lipid/water interference, yielding calibrated concentration estimates across buffers and formulations. A multipixel SNR strategy improves detection at low signal. This in situ assay offers a high-throughput readout for manufacturing and quality control of mRNA formulations.
No takes yet. Share an insight, caveat, or question.
Sullivan et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: