Key result
AF trigger veins exhibit a ~10 ms shorter minimum local cycle length versus non-trigger sites.
Why the study?
AF triggers are usually identified at onset, but the electrophysiological behavior of trigger sites during ongoing AF remains incompletely understood.
Does ultra-high-resolution mapping identify specific electrophysiological characteristics at atrial fibrillation trigger sites during ongoing atrial fibrillation?
Observational (n=45)
Does ultra-high-resolution mapping identify specific electrophysiological characteristics at atrial fibrillation trigger sites during ongoing atrial fibrillation?
Atrial fibrillation trigger sites are characterized by a markedly shorter minimum local cycle length during ongoing AF, providing a potential mapping target when conventional trigger mapping is inconclusive.
Introduction Atrial fibrillation (AF) triggers are commonly identified at the onset of AF, but the electrophysiological behavior of trigger sites during ongoing AF remains incompletely understood. This study aimed to characterize local electrogram properties at AF trigger sites during ongoing AF using an ultra‐high‐resolution mapping system. Methods and Results We retrospectively studied 45 consecutive patients with pulmonary vein (PV) or superior vena cava (SVC) triggers who underwent mapping during ongoing AF. The local cycle length (L‐CL) and the proportion of the activation duration within the L‐CL (duty cycle, DC) were assessed using an automated mapping tool (Ockham, Boston Scientific) and were compared among trigger veins, non‐trigger PVs, the left atrium (LA), non‐trigger SVC, and the right atrium (RA). A total of 56 AF triggers were documented. Trigger veins exhibited a significantly shorter minimum L‐CL than the non‐trigger PVs, LA, non‐trigger SVC, and RA (median, 119, 129, 131, 157, and 139 ms, respectively; p < 0.0001). The quartiles and maximum L‐CL values and all DC parameters were comparable among the trigger veins, non‐trigger PVs, and LA. A receiver operating characteristic analysis demonstrated that the minimum L‐CL had the strongest association with trigger sites (area under the curve, 0.856). Conclusion AF trigger sites were characterized by a markedly shorter minimum L‐CL during ongoing AF, suggesting transient rapid activity. These findings provide mechanistic insights into the electrophysiological behavior of AF trigger sites and may offer complementary information when conventional trigger mapping is inconclusive.
No takes yet. Share an insight, caveat, or question.
Nakamura et al. (2026) conducted an observational in Atrial fibrillation (n=45). Ultra-high-resolution mapping of trigger veins vs. Non-trigger sites (PVs, LA, SVC, RA) was evaluated on Minimum local cycle length (L-CL) (AUC 0.856, p=<0.0001). Atrial fibrillation trigger veins exhibited a significantly shorter minimum local cycle length compared to non-trigger sites during ongoing AF (median 119 ms vs 129-157 ms; p<0.0001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: