Key result
Finger PPG-derived PRV yields ~0.88 correlation with HRV in adults with spinal cord injury.
Why the study?
The validity of pulse rate variability as an alternative to heart rate variability for measuring psychophysiological function is unclear, especially in adults with spinal cord injury.
Does pulse rate variability (PRV) provide a valid alternative to heart rate variability (HRV) for measuring psychophysiological function in adults with spinal cord injury?
Cross-Sectional (n=89)
Does pulse rate variability (PRV) provide a valid alternative to heart rate variability (HRV) for measuring psychophysiological function in adults with spinal cord injury?
Pulse rate variability derived from reflective finger-based PPG is a valid proxy for heart rate variability in tracking psychophysiological function in adults with spinal cord injury.
Answers are grounded in this paper and cite their sources.
May offer convenient PRV alternative to HRV in spinal cord injury; leaves open prospective validation before clinical use.
Pulse rate variability (PRV) is often used as an alternative to heart rate variability (HRV) to measure psychophysiological function. However, its validity to do so is unclear, especially in adults with spinal cord injury (SCI). This study compared PRV and HRV in adults with higher-level SCI (SCI-H, n = 23), lower-level SCI (SCI-L, n = 22), and able-bodied participants (AB n = 44), in a seated position as a function of performance in a reactivity task (Oxford Sleep Resistance Test: OSLER). PRV and HRV was measured using reflective finger-based photoplethysmography (PPG) and electrocardiography, respectively, at baseline, immediately post-OSLER, and after five-minute recovery. Agreement between PRV and HRV was determined by Bland-Altman analysis and differences between PRV and HRV over time by linear mixed effects model (LMM) analysis. Concurrent validity was assessed through correlation analyses between PRV and HRV. Additional correlation analyses were performed with psychosocial factors. Results indicated insufficient to moderate agreement between PRV and HRV. LMM analyses indicated no differences over time for standard deviation of normal-to-normal intervals and low-frequency power but significant differences for root mean square of successive differences and high frequency power. Nevertheless, PRV and HRV were highly correlated (Median r = .878 (.675-.990)) during all assessment periods suggesting sufficient concurrent validity. Similar correlation patterns were also found for PRV and HRV with psychosocial outcomes. While differences existed, results suggest PRV derived from reflective finger-based PPG is a valid proxy of HRV in tracking psychophysiological function in adults with SCI and could therefore be used as a more accessible monitoring tool.
No takes yet. Share an insight, caveat, or question.
Schoffl et al. (2023) conducted a cross-sectional in Spinal cord injury (n=89). Pulse rate variability (PRV) via photoplethysmography vs. Heart rate variability (HRV) via electrocardiography was evaluated on Agreement and concurrent validity between PRV and HRV (Median r = 0.878, 95% CI 0.675-0.990). Pulse rate variability derived from reflective finger-based PPG was highly correlated with heart rate variability in adults with spinal cord injury.
Synapse has enriched 10 related papers. Consider them for comparative context: