Key result
Interatrial conduction time strongly predicted atrial fibrillation during electrophysiological studies (AUC 0.852; p < 0.001), alongside maximum P-wave duration and maximum Ppeak-Pend interval.
Why the study?
Several P-wave parameters reflect atrial conduction characteristics and predict AF, but the relationship between maximum P-wave duration, new P-wave parameters, and atrial conduction times, along with their predictive value for AF during electrophysiological studies, needed evaluation.
Do P-wave parameters and atrial conduction times predict the occurrence of atrial fibrillation during electrophysiological studies?
Cross-Sectional (n=153)
Do P-wave parameters and atrial conduction times predict the occurrence of atrial fibrillation during electrophysiological studies?
Atrial conduction times and specific P-wave parameters, particularly the maximum Ppeak-Pend interval and PMax, are significant predictors of atrial fibrillation occurrence during electrophysiological studies.
OBJECTIVE: Several P-wave parameters reflect atrial conduction characteristics and have been used to predict atrial fibrillation (AF). The aim of this study was to determine the relationship between maximum P-wave duration (PMax) and new P-wave parameters, with atrial conduction times (CT), and to assess their predictive value of AF during electrophysiological studies (AF-EPS). SUBJECTS AND METHODS: This was a cross-sectional study in 153 randomly selected patients aged 18-70 years, undergoing EPS. The patients were divided into 2 groups designated as no AF-EPS and AF-EPS, depending on whether AF occurred during EPS or not. Different P-wave parameters and atrial CT were compared for both study groups. Subsequently, the predictive value of the P-wave parameters and the atrial CT for AF-EPS was evaluated. RESULTS: The values of CT, PMax, and maximum Ppeak-Pend interval (Pp-eMax) were significantly higher in patients with AF-EPS. Almost all P-wave parameters were correlated with the left CT. PMax, Pp-eMax, and CT were univariate and multivariate predictors of AF-EPS. The largest ROC area was presented by interatrial CT (0.852; p < 0.001; cutoff value: ≥82.5 ms; sensitivity: 91.1%; specificity: 81.1%). Pp-eMax showed greater sensitivity (79.5%) to discriminate AF-EPS than PMax (72.7%), but the latter had better specificity (60.4% vs. 41.5%). CONCLUSIONS: Left atrial CT were directly and significantly correlated with PMax and almost all the parameters of the second half of the P-wave. CT, PMax, and Pp-eMax (new parameter) were good predictors of AF-EPS, although CT did more robustly.
No takes yet. Share an insight, caveat, or question.
Puerta et al. (2021) conducted a cross-sectional in Atrial fibrillation (n=153). P-wave parameters and atrial conduction times was evaluated on Atrial fibrillation during electrophysiological studies (AF-EPS) (AUC 0.852, p=< 0.001). Interatrial conduction time strongly predicted atrial fibrillation during electrophysiological studies (AUC 0.852; p < 0.001), alongside maximum P-wave duration and maximum Ppeak-Pend interval.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: