Key result
Stacked Restricted Boltzmann Machine model automatically classifies ECG heartbeats with ~100% patient-independent accuracy.
Why the study?
Does a stacked RBM model improve the accuracy of automated arrhythmia detection from ECG signals?
Does a stacked RBM model improve the accuracy of automated arrhythmia detection from ECG signals?
A stacked Restricted Boltzmann Machine model provides highly accurate, automated classification of ECG heartbeats into arrhythmia classes without requiring handcrafted feature extraction.
Answers are grounded in this paper and cite their sources.
May advance automated ECG arrhythmia detection; hypothesis-generating and requires prospective validation before clinical adoption.
Significant advances in deep learning techniques have made it possible to offer technologically advanced methods to detect cardiac abnormalities. In this study, we have proposed a new deep learning based Restricted Boltzmann machine (RBM) model for the classification of arrhythmias from Electrocardiogram (ECG) signal. The work is divided into three phases where, in the first phase, signal processing is performed, including the normalization of the heartbeats as well as the segmentation of the heartbeats. In the second phase, the stacked RBM model is implemented which extracts the essential features from the ECG signal. Finally, a SoftMax activation function is used that classifies the ECG signal into four types of heartbeat classes according to ANSI/AAMA standards. This stacked RBM model is offered as three types of experiments, patient independent data classification for multi-class, patient independent data for binary classification, and patient specific classification. The best result was obtained using patient independent binary classification with an overall accuracy of 99.61%. For Patient Independent Multi Class classification, accuracy obtained was 98.61% and for patient specific data, the accuracy was 95.13%. The experimental results shows that the developed RBM model has better performance in terms of accuracy, sensitivity and specificity as compared to work mentioned in the other research papers. Article highlights The proposed RBM model is skilled to automatically classify ECG heartbeat according to the ANSI- AAMI standards with accuracy, Recall, specificity. The performance of the RBM model to correctly classify heartbeat classes was found to be improved. The model is fully automatic, hence there is no requirement of additional system like feature extraction, feature selection, and classification.
No takes yet. Share an insight, caveat, or question.
Pandey et al. (2021) studied Arrhythmia (n=47). Stacked Restricted Boltzmann Machine (RBM) model vs. Other state-of-the-art machine learning classifiers was evaluated on Overall accuracy for patient-independent binary classification. The proposed stacked Restricted Boltzmann Machine model automatically classified ECG heartbeats with an overall accuracy of 99.61% for patient-independent binary classification.
Synapse has enriched 10 related papers. Consider them for comparative context: