A novel method for implementing a variable hysteresis band current controller is described which achieves constant switching frequency without requiring a precise knowledge of the motor parameters. The controller works by using feedback and feedback variables to create a variable hysteresis band envelope, and then compensating for the interaction between phase back-EMFs that occurs when the neutral of a three-phase motor is left floating. The controller has good dynamic and steady-state response, and its performance is substantially immune to variations in the inverter DC supply voltage and motor parameters. It can be readily implemented in hardware, and only requires a few additional components compared to a conventional hysteresis current controller. Analytical, hardware implementation, simulation, FFT (fast Fourier transform) analysis, and experimental results are presented.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
No takes yet. Share an insight, caveat, or question.
Yao et al. (2002) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: