Why the study?
Differences in the incidence of adverse clinical events according to stent type in patients with diabetes remained to be elucidated.
Does biodegradable polymer sirolimus-eluting stents (BP-SES) reduce adverse clinical events compared to durable polymer everolimus-eluting stents (DP-EES) in patients with diabetes mellitus and stable angina pectoris?
Does biodegradable polymer sirolimus-eluting stents (BP-SES) reduce adverse clinical events compared to durable polymer everolimus-eluting stents (DP-EES) in patients with diabetes mellitus and stable angina pectoris?
In patients with diabetes and stable angina, the use of biodegradable polymer sirolimus-eluting stents was associated with a higher incidence of target lesion revascularization and device-oriented clinical endpoints compared to durable polymer everolimus-eluting stents.
BP-SES may increase TLR risk in diabetic stable angina; hypothesis-generating and should not yet change stent selection.
BACKGROUND: Diabetes mellitus is a risk for increased incidence of adverse clinical events after percutaneous coronary intervention. However, the difference in the incidence of adverse clinical events according to stent type in patients with diabetes remains to be elucidated. In the present study, we aimed to compare the clinical outcomes between patients treated with the biodegradable polymer sirolimus-eluting stents (BP-SES) and the durable polymer everolimus-eluting stents (DP-EES) among patients with diabetes. METHODS: Among 631 lesions in 510 consecutive patients treated with either BP-SES or DP-EES, 165 lesions in 141 patients with diabetes mellitus and stable angina pectoris were identified and classified into the BP-SES group (48 lesions in 44 patients) and the DP-EES group (117 lesions in 100 patients). The incidence of adverse clinical events after stent implantation was compared between the 2 groups. RESULTS: There was no significant difference in the prevalence of conventional risk factors, lesion characteristics, and procedural characteristics between the 2 groups. During median 386 [334-472] days follow-up, the incidence of target lesion revascularization (11.4 vs. 2.0%, p = 0.003) and device-oriented clinical endpoint (13.6 vs. 6.0%, p = 0.035) in the BP-SES group was significantly greater than that in the DP-EES group. A univariate model demonstrated that the BP-SES usage was significantly associated with the higher incidence of target lesion revascularization (odds ratio, 6.686; 95% confidence interval, 1.234-36.217; p = 0.028). CONCLUSION: BP-SES was associated with the greater incidence of TLR than the DP-EES in patients with diabetes mellitus. Further studies with larger cohorts and longer follow-up are required to confirm the present results.
No takes yet. Share an insight, caveat, or question.
Kakizaki et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: