Key result
Wrist-worn PPG wearables detect AF with ~96% sensitivity and high specificity across studies.
Why the study?
Early detection of AF is essential to prevent severe consequences, but the additional clinical value of low-cost, wrist-worn photoplethysmography-based devices compared to implantable continuous monitors has yet to be determined.
Do wrist-worn photoplethysmography-based wearables accurately detect atrial fibrillation?
Do wrist-worn photoplethysmography-based wearables accurately detect atrial fibrillation?
Answers are grounded in this paper and cite their sources.
Wrist-worn PPG wearables demonstrate high accuracy for detecting atrial fibrillation in controlled settings, but further research is needed to validate their performance and clinical utility for long-term ambulatory monitoring.
Early detection and diagnosis of atrial fibrillation (AF) is essential in order to prevent stroke and other severe health consequences. The challenges in diagnosing AF arise from its intermittent and asymptomatic nature. Wrist-worn devices that use monitoring based on photoplethysmography have been proposed recently as a possible solution because of their ability to monitor heart rate and rhythm for long periods of time at low cost. Long-term continuous monitoring with implantable devices has been shown to increase the percentage of detected AF episodes, but the additional value of wrist-worn devices has yet to be determined. In this review, we present the state of the art in AF detection with wrist-worn devices, discuss the potential of the technology and current knowledge gaps, and propose directions for future research. The state-of-the-art methods show excellent accuracy for AF detection. However, most of the studies were conducted in hospital settings, and more studies showing the accuracy of the technology for ambulatory long-term monitoring are needed. Objective comparison of results and methodologies among different studies currently is difficult due to the lack of adequate public datasets.
No takes yet. Share an insight, caveat, or question.
Eerikäinen et al. (2020) conducted a review in Atrial fibrillation. Wrist-worn photoplethysmography-based wearables vs. Standard ECG monitoring was evaluated on Diagnostic accuracy (sensitivity and specificity) for atrial fibrillation detection. Wrist-worn photoplethysmography-based wearables demonstrated excellent accuracy for atrial fibrillation detection, with a median sensitivity of 96.2% and specificity of 97.7% across evaluated studies.