Key result
Laser balloon ablation shows similar silent cerebral event rates to cryoballoon ablation in paroxysmal AF.
Why the study?
Different energy sources of balloon-based ablation for pulmonary vein isolation cause different endothelial damage and coagulation responses linked to thromboembolic risk, but their comparative impacts were unclear.
Does laser balloon ablation compared to cryoballoon ablation affect coagulation biomarkers and silent cerebral events in patients with paroxysmal atrial fibrillation?
Cohort (n=105)
Single-blind
No
Does laser balloon ablation compared to cryoballoon ablation affect coagulation biomarkers and silent cerebral events in patients with paroxysmal atrial fibrillation?
Laser balloon ablation and cryoballoon ablation produce different periprocedural biomarker profiles, with LBA showing higher late coagulation activity, though both result in similar rates of silent cerebral events and clinical efficacy.
Answers are grounded in this paper and cite their sources.
Comparable silent cerebral event rates support periprocedural safety equivalence of both techniques; leaves open whether biomarker differences influence longer-term thromboembolic risk.
BackgroundDifferent energy sources of balloon-based ablation for pulmonary vein isolation cause different kinds of endothelial damage and coagulation responses associated with thromboembolic risk.ObjectivesThe study sought to compare the impact of different balloon-based ablation, cryoballoon ablation (CBA) and laser balloon ablation (LBA), on coagulation/fibrinolysis biomarkers and silent cerebral events (SCEs) in paroxysmal atrial fibrillation.MethodsParoxysmal atrial fibrillation patients who underwent pulmonary vein isolation using either CBA (n = 52) or LBA (n = 53) without radiofrequency touch-up ablation were eligible. Time course (day 0 [before ablation], day 1, day 2, and day 28) of myocardial enzymes and inflammatory and coagulation/fibrinolysis biomarkers was evaluated during the perioperative period. Brain magnetic resonance imaging was performed within 2 days after the procedure to evaluate SCEs.ResultsThere was no difference in patient characteristics between CBA and LBA.CBA had greater myocardial injury (troponin I and creatine kinase-MB) and lower inflammatory reaction (white blood cell count and neutrophil/lymphocyte ratio) than LBA. The coagulation biomarkers maximally increased by day 2 and then decreased in both groups. In day 28, the serum prothrombin fragment 1+2 and D-dimer levels in LBA were significantly higher than the values in CBA. The fibrinolysis biomarker (plasmin-α2 plasmin inhibitor complex) did not increase after the procedure in either group. The incidence of SCEs was comparable between CBA and LBA (11% vs 15%; P = .591). No thromboembolic event was observed.ConclusionCBA and LBA had different effects on myocardial injury, inflammatory reaction, and coagulation activity but did not affect the incidence of thromboembolic events. LBA had significantly higher coagulation activity in day 28 and may require more careful postprocedural anticoagulation than CBA. Different energy sources of balloon-based ablation for pulmonary vein isolation cause different kinds of endothelial damage and coagulation responses associated with thromboembolic risk. The study sought to compare the impact of different balloon-based ablation, cryoballoon ablation (CBA) and laser balloon ablation (LBA), on coagulation/fibrinolysis biomarkers and silent cerebral events (SCEs) in paroxysmal atrial fibrillation. Paroxysmal atrial fibrillation patients who underwent pulmonary vein isolation using either CBA (n = 52) or LBA (n = 53) without radiofrequency touch-up ablation were eligible. Time course (day 0 [before ablation], day 1, day 2, and day 28) of myocardial enzymes and inflammatory and coagulation/fibrinolysis biomarkers was evaluated during the perioperative period. Brain magnetic resonance imaging was performed within 2 days after the procedure to evaluate SCEs. There was no difference in patient characteristics between CBA and LBA.CBA had greater myocardial injury (troponin I and creatine kinase-MB) and lower inflammatory reaction (white blood cell count and neutrophil/lymphocyte ratio) than LBA. The coagulation biomarkers maximally increased by day 2 and then decreased in both groups. In day 28, the serum prothrombin fragment 1+2 and D-dimer levels in LBA were significantly higher than the values in CBA. The fibrinolysis biomarker (plasmin-α2 plasmin inhibitor complex) did not increase after the procedure in either group. The incidence of SCEs was comparable between CBA and LBA (11% vs 15%; P = .591). No thromboembolic event was observed. CBA and LBA had different effects on myocardial injury, inflammatory reaction, and coagulation activity but did not affect the incidence of thromboembolic events. LBA had significantly higher coagulation activity in day 28 and may require more careful postprocedural anticoagulation than CBA.
No takes yet. Share an insight, caveat, or question.
Koshikawa et al. (2024) conducted a cohort in Paroxysmal atrial fibrillation (n=105). Laser balloon ablation (LBA) vs. Cryoballoon ablation (CBA) was evaluated on Incidence of silent cerebral events (SCEs) within 2 days after the procedure (p=0.591). Laser balloon ablation and cryoballoon ablation resulted in a comparable incidence of silent cerebral events in patients with paroxysmal atrial fibrillation.
Synapse has enriched 10 related papers. Consider them for comparative context: