Why the study?
PVC burden is a clinically important metric in PVC-induced cardiomyopathy, and this study aimed to characterize the performance of a novel ICM algorithm detecting single PVCs and sequences to estimate 24-hour PVC burden.
Does a novel PVC detection algorithm in an insertable cardiac monitor accurately detect PVCs and estimate daily PVC burden compared to standard Holter monitoring?
Does a novel PVC detection algorithm in an insertable cardiac monitor accurately detect PVCs and estimate daily PVC burden compared to standard Holter monitoring?
A novel insertable cardiac monitor algorithm accurately detects premature ventricular contractions and estimates daily burden, correlating strongly with gold-standard Holter monitoring.
May enable continuous PVC monitoring via ICM; leaves open prospective validation versus Holter before clinical use.
Background: Premature ventricular contraction (PVC) burden is a clinically important metric in the context of PVC-induced cardiomyopathy and is commonly obtained via ambulatory electrocardiogram (ECG) monitoring. Objective: The purpose of this analysis is to characterize the performance of a novel PVC detection algorithm capable of identifying single PVCs and PVC sequences (couplets and triplets) for estimation of 24-hour PVC burden in an insertable cardiac monitor (ICM). Methods: Performance of the ICM algorithm for detecting PVCs was validated by replaying 748 patient-triggered ICM-recorded ECG episodes from 184 patients through the ICM device. To assess performance over longer ambulatory periods, a validated software model equivalent of the implemented ICM algorithm was evaluated against a 24-hour Holter dataset of 89 patients. The model also was used to evaluate performance on an established reference library from the Massachusetts Institute of Technology and Beth Israel Hospital (MIT-BIH Arrhythmia Database) as a basis of comparison with other published algorithms. Results: = 0.95. The sensitivity for identifying patients with PVC burdens ≥10% was 84%, with a patient-level positive predictive value (PPV) of 100%. Beat-level sensitivity of the PVC algorithm evaluated against the MIT-BIH dataset was 87.9% with a PPV of 96.4%. Conclusion: The ICM algorithm reliably detects PVCs with high sensitivity and specificity. Twenty-four-hour PVC burden measurements demonstrated a strong correlation with a gold standard 12-lead Holter and may provide utility for identifying patients at risk for worsening left ventricular function.
No takes yet. Share an insight, caveat, or question.
Siejko et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: