Why the study?
No evidence existed evaluating the safety of left atrial appendage occlusion or its effect on cardiac implantable electronic device function in patients with a CIED.
Does the presence of a cardiac implantable electronic device (CIED) affect the safety, procedural success, or lead integrity during percutaneous left atrial appendage occlusion (LAAO)?
Does the presence of a cardiac implantable electronic device (CIED) affect the safety, procedural success, or lead integrity during percutaneous left atrial appendage occlusion (LAAO)?
Answers are grounded in this paper and cite their sources.
Percutaneous left atrial appendage occlusion is safe and feasible in patients with a pre-existing cardiac implantable electronic device, without causing significant lead displacement or dysfunction.
BACKGROUND: Left atrial appendage occlusion (LAAO) may be a viable option for stroke prevention in patients with non-valvular atrial fibrillation and a contraindication for oral anticoagulation. No evidence evaluating the safety of this procedure in patients with a cardiac implantable electronic device (CIED) exists. The aim of this study was to evaluate whether CIED function is affected by LAAO and to explore LAAO procedural characteristics and complications in patients with a CIED. METHODS: This single-center cohort study included consecutive patients scheduled for percutaneous LAAO. Patients with a CIED prior to LAAO were selected and compared to the patients without CIED, concerning procedural characteristics and peri-procedural complications. In the group of patients with CIEDs, essential pacemaker integrity parameters were compared before and after the procedure to detect possible micro and macro lead displacements. The 245 patients without CIED were younger, and HAS-BLED-score was slightly lower (69.4 ± 8.2 years, p < 0.001; 2.8 ± 1.0, p = 0.022). Patients without CIED more frequently underwent LAAO combined with catheter ablation (p = 0.002). All other procedural characteristics were comparable between both groups. No visible lead displacement was observed on chest X-ray after LAAO. Additionally, no differences in impedance, threshold, or intracardiac sensing in various CIED lead locations were found prior versus post LAAO. CONCLUSION: This study supports the feasibility and safety of LAAO in patients with a CIED.
No takes yet. Share an insight, caveat, or question.
Staal et al. (2023) studied this question.