The objective of the present study is to evaluate the corrosion properties of pipeline steels in CO2/H2S/H2O mixtures with different amounts of water (undersaturated and saturated) related to a natural gas transportation pipeline. Corrosion behavior of carbon steel, 1Cr steel, and 3Cr steel was evaluated using an autoclave with different combinations of CO2 partial pressure and temperature (8 MPa/25°C and 12 MPa/80°C) with 200 ppm H2S. The corrosion rate of samples was determined by weight-loss measurements. The surface morphology and the composition of the corrosion product layers were analyzed using surface analytical techniques (scanning electron microscopy and energy dispersive x-ray spectroscopy). Results showed that the corrosion rate of materials in supercritical and liquid phase CO2 saturated with water was very low (<0.01 mm/y). However, adding 200 ppm of H2S to the supercritical and liquid CO2 system caused mild corrosion (<0.5 mm/y). Reducing water content to 100 ppm in the supercritical and liquid CO2 systems with 200 ppm of H2S reduced the corrosion rate to less than 0.01 mm/y.
No takes yet. Share an insight, caveat, or question.
Choi et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: