May 30, 20260 citationsOpen Access

The Diagnostic Value of Indocyanine Green in the Assessment of Depth of Burn Injuries: A Systematic Review

View Full Paper
MHMarie K. HilgarthSKSamuel KnoedlerGHGabriel Hundeshagen

Key Points

  • This review aims to evaluate the ability of indocyanine green fluorescence imaging to assess burn depth compared to other methods.
  • Conducted a systematic literature search in PubMed/MEDLINE, Cochrane, and Google Scholar.
  • Included studies from 1995 to 2024 comparing ICG fluorescence with clinical and histological assessments.
  • Performed data extraction and risk of bias assessment using the Newcastle-Ottawa Scale.
  • Nine studies with 151 patients met inclusion criteria, revealing substantial methodological heterogeneity.
  • ICG fluorescence imaging showed high accuracy in identifying nonviable tissue in some studies, but inconsistencies in differentiating between superficial and deep partial-thickness burns.
  • One study found ICG assessment reduced excision in 50% of assessed burn sites.

Abstract

Background: Accurate assessment of burn depth remains a clinical challenge and requires specific training. To improve diagnostic accuracy, various technical methods have been developed. This review summarizes current evidence on indocyanine green (ICG) fluorescence imaging for burn depth assessment and compares its performance with clinical, histological, and alternative modalities such as Laser Doppler imaging (LDI). Methods: A systematic literature search was conducted in PubMed/MEDLINE, Cochrane and Google Scholar to identify studies evaluating burn depth using ICG fluorescence imaging. Studies from 1995 to 2024 were included if they compared ICG to at least one reference method (clinical assessment, biopsy, or other technical modalities). Data extraction was performed independently by two reviewers. Risk of bias was assessed using the Newcastle-Ottawa Scale. The study selection workflow is shown in the PRISMA 2020 flow diagram for systematic reviews. Results: Nine studies with a total of 151 patients, published between 1995 and 2024, met the inclusion criteria. Results were synthesized descriptively due to substantial methodological heterogeneity. Two studies reported high accuracy of ICG fluorescence imaging for identifying nonviable tissue and supporting surgical planning, although differentiation between superficial and deep partial-thickness burns (SPTBs/DPTBs) was inconsistent. In one study, ICGA-guided assessment reduced or avoided excision in 10 of 20 burn sites (50%). Yet heterogeneity in measurement protocols, cut-off values, and reference standards limited comparability across studies. Conclusions: Due to its limited accuracy in differentiating SPTBs and DPTBs, ICG imaging has restricted utility for burn depth assessment, though it may still offer intraoperative benefit during necrosectomy. Registration: PROSPERO International prospective register of SRs by the National Institute of Health Research (CRD420251161190).