Evaluates reduced iodine load in pulmonary artery imaging, suggesting clinical benefits.
introduction: To evaluate the feasibility of using an ultra-low concentration iodine contrast agent (160 mgI/mL) combined with dual-layer detector spectral CT for pulmonary CT angiography (CTPA), aiming to significantly reduce iodine load while assessing whether the image quality meets clinical diagnostic requirements. Methods: A total of 143 patients who underwent CT pulmonary angiography (CTPA) between May 2024 and May 2025 were enrolled. After excluding 19 patients with suboptimal image quality due to technical factors, 124 patients were included in the final analysis (spectral group: n = 64; control group: n = 60). Patients were assigned to either a spectral group (100 kV, 160 mgI/mL contrast, 25 mL, 2.5 mL/s) or a control group (120 kV, 350 mgI/mL contrast, 35 mL, 4 mL/s). In the spectral group, images were reconstructed using conventional CT and virtual monoenergetic imaging at 40, 70, and 110 keV. The control group underwent conventional CT imaging only. Image quality, CT attenuation values, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and radiation doses were assessed and compared between the two groups. Results: The spectral group successfully reduced the iodine intake per examination to 4 g, representing a significant 67% reduction compared to the conventional dose (12.2 g). No statistically significant differences were found in subjective image quality scores or objective noise levels between the two groups, with both meeting diagnostic standards. Although the tube voltage was lower in the spectral group, the radiation dose metrics (CTDIvol, DLP, ED) showed no significant differences from the control group, attributable to automatic tube current modulation. Discussion: This study confirms that utilizing an ultra-low concentration iodine contrast agent (160 mgI/mL) with a volume of 25 mL and an injection flow rate of 2.5 mL/s, combined with dual-layer detector spectral CT for pulmonary CTA (CTPA), achieves diagnostic image quality comparable to conventional CT while significantly reducing the iodine load. Specifically, this ultra-low dose protocol cuts the iodine intake per examination to 4 g, a 67% reduction compared to conventional protocols, which is crucial for lowering the risk of contrast-induced nephropathy (CIN), especially in patients with renal impairment. Compared to the control group, the spectral group not only used a lower iodine concentration but also a reduced tube voltage (100 kV vs. 120 kV). Despite the lower voltage, there were no significant differences in radiation dose metrics (CTDIvol, DLP, ED) between the two groups, likely due to the compensatory effect of automatic tube current modulation (DoseRight) using a fixed noise index of 18. Innovatively, this study diluted the contrast agent concentration to 160 mgI/mL and utilized spectral CT to reconstruct 40 keV monoenergetic (Mono-E) images. This virtual keV enhancement increased CT values and improved contrast, effectively offsetting the impact of the reduced concentration. Subjective and objective image quality scores showed no significant differences from the control group and met clinical diagnostic requirements. Furthermore, the iodine load was drastically reduced from the conventional 12.2 g to 4 g. Limitations include: (1) This was a single-center study with a small sample size, potentially introducing selection bias and limiting the assessment of rare adverse events. It also lacked stratified analysis based on renal function. (2) Changes in patient renal function were not monitored, so the direct impact on CIN incidence could not be evaluated. When promoting this protocol, consider that it requires high-quality equipment (spectral CT), may need parameter adjustments for obese patients (BMI >30 kg/m²), and standardized procedures across different hospitals still need improvement. In conclusion, the ultra-low concentration iodine protocol combined with spectral CT provides diagnostic image quality while significantly reducing iodine load, offering substantial clinical benefits, particularly for patients at risk of CIN. Conclusion: Dual-layer spectral CT combined with 40 keV virtual monoenergetic imaging allowed pulmonary artery imaging with markedly reduced iodine load while maintaining diagnostic image quality comparable to that of the conventional protocol.
No takes yet. Share an insight, caveat, or question.
Yang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: