Key result
Specular Reflection Vascular Imaging successfully extracted carotid artery and jugular vein waveforms, providing a 6-fold improvement in signal strength over a comparator remote PPG dataset.
Why the study?
The jugular venous pulse waveform reflects mechanical cardiac function, but technologies to aid its clinical evaluation and interpretation are currently lacking.
Does Specular Reflection Vascular Imaging (SRVI) improve the extraction of neck vessel pressure waveforms compared to remote PPG in healthy volunteers?
Observational (n=10)
No
Does Specular Reflection Vascular Imaging (SRVI) improve the extraction of neck vessel pressure waveforms compared to remote PPG in healthy volunteers?
Specular Reflection Vascular Imaging is a feasible novel modality that provides a 6-fold improvement in signal strength over remote PPG for extracting jugular venous and carotid artery pulse waveforms.
SRVI may enable stronger remote neck vessel signals in volunteers; leaves open clinical translation pending larger validation studies.
Cardiovascular disease (CVD) is a leading cause of death worldwide and was responsible for 31% of all deaths in 2015. Changes in fluid pressures within the vessels of the circulatory system reflect the mechanical function of the heart. The jugular venous (JV) pulse waveform is an important clinical sign for assessing cardiac function. However, technology able to aid evaluation and interpretation are currently lacking. The goal of the current study was to develop a remote monitoring tool that aid clinicians in robust measurements of JV pulse waveforms. To address this need, we have developed a novel imaging modality, Specular Reflection Vascular Imaging (SRVI). The technology uses specular reflection for visualization of skin displacements caused by pressure pulsations in blood vessels. SRVI has been tested on 10 healthy volunteers. 10-seconds videos of the neck illuminated with a diffuse light source were captured at 250 fps. SRVI was able to identify and discriminate skin displacements caused by carotid artery and jugular vein pulsations to extract both carotid artery and jugular vein waveforms, making them easier to be visualized and interpreted. The method provided a 6-fold improvement in signal strength over a comparator remote PPG dataset. The current pilot study is a proof-of-concept demonstration of the potential of Specular Reflection Vascular Imaging for extraction of JV pulse waveforms.
No takes yet. Share an insight, caveat, or question.
Saiko et al. (2022) conducted an observational in Healthy volunteers (n=10). Specular Reflection Vascular Imaging (SRVI) vs. Remote photoplethysmography (PPG) was evaluated on Signal strength of extracted neck vessel pressure waveforms. Specular Reflection Vascular Imaging successfully extracted carotid artery and jugular vein waveforms, providing a 6-fold improvement in signal strength over a comparator remote PPG dataset.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: