Why the study?
Do adverse IVUS findings (small lumen area, residual stenosis, edge dissection, tissue protrusion) predict early stent thrombosis in patients with acute myocardial infarction undergoing primary PCI?
Population
401 patients with acute myocardial infarction undergoing primary percutaneous intervention with baseline…
Comparison
Adverse IVUS features vs Absence of adverse IVUS features
Design
Cohort
Follow-up
≤30 days
Authors
Loading...
Adverse IVUS features were associated with early stent thrombosis after primary PCI; hypothesis-generating and requires randomized confirmation before guiding practice.
Do adverse IVUS findings (small lumen area, residual stenosis, edge dissection, tissue protrusion) predict early stent thrombosis in patients with acute myocardial infarction undergoing primary PCI?
Smaller final lumen area and inflow/outflow disease (residual stenosis or dissection) on IVUS are strongly associated with early stent thrombosis after primary PCI for acute myocardial infarction.
Choi et al. (2011) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: