Key result
The ultrasound-guided robotically-actuated delivery sheath achieved stabilization in a beating heart mitral valve model with a mean absolute tracking error of 1.31 mm at 20 beats per minute.
An ultrasound-guided robotically-actuated delivery sheath can autonomously stabilize within a beating heart mitral valve model with sub-2mm accuracy at 20 BPM, potentially facilitating minimally invasive beating-heart mitral valve repair.
Answers are grounded in this paper and cite their sources.
Supports feasibility in animal beating-heart models; leaves open translation to human mitral repair.
Minimally invasive mitral valve (MV) repair surgery significantly reduces trauma compared to an open heart procedure, which enables fast recovery and treatment to high-risk patients. However, limited vision and dexterity of the instrument at the treatment location poses a challenge for minimally invasive surgery. Additionally, MV repair surgery performed without cardiopulmonary bypass often requires the surgeon to deal with beating heart motions. By autonomous stabilization of the instrument, a virtually-still treatment location could be provided. This allows the surgeon to perform surgery as if the heart was stopped. In this study, we present and evaluate a framework that assists the surgeon by stabilizing the instrument for the beating heart MV motions. Our work contributes a robotically-actuated delivery sheath (RADS), which is stabilized in a realistic and functional MV model embedded in a heart motion system. The heart motion system is mounted on a six degrees-of-freedom Stewart platform, which reproduces beating heart MV motions based on pre-operative patient data obtained from three-dimensional magnetic resonance and ultrasound images. Experimental results shows stabilization of the RADS in a beating heart MV model with a mean absolute tracking error of 1.31 mm. The presented framework for stabilization of the RADS in the beating heart could be applicable to a wide variety of existing and potential future cardiovascular interventions.
No takes yet. Share an insight, caveat, or question.
Vrooijink et al. (2016) studied Mitral valve repair (experimental model). Robotically-Actuated Delivery Sheath (RADS) with ultrasound-guided stabilization was evaluated on Mean absolute tracking error. The ultrasound-guided robotically-actuated delivery sheath achieved stabilization in a beating heart mitral valve model with a mean absolute tracking error of 1.31 mm at 20 beats per minute.
Synapse has enriched 10 related papers. Consider them for comparative context: