Key result
Edge-to-edge mitral valve repair resulted in significantly higher intraoperative peak (10.7 vs 7.1 mmHg) and mean (4.3 vs 2.8 mmHg) transmitral pressure gradients compared to conventional repair.
Why the study?
Does edge-to-edge mitral valve repair increase intraoperative transmitral pressure gradients compared to conventional repair in patients undergoing surgery for mitral regurgitation?
Cohort (n=552)
No
Does edge-to-edge mitral valve repair increase intraoperative transmitral pressure gradients compared to conventional repair in patients undergoing surgery for mitral regurgitation?
Edge-to-edge mitral valve repairs result in higher intraoperative transmitral pressure gradients than conventional repairs, but these mildly elevated gradients are generally well tolerated and do not necessarily indicate iatrogenic mitral stenosis.
Answers are grounded in this paper and cite their sources.
Edge-to-edge repair may warrant cautious gradient interpretation to avoid overdiagnosing stenosis; leaves open long-term clinical impact versus conventional repair.
OBJECTIVE: Edge-to-edge repair of the mitral valve (MV) has been described as a viable option used for the surgical management of mitral regurgitation (MR). Based on the significant changes in MV geometry associated with this technique, we hypothesized that edge-to-edge MV repairs are associated with higher intraoperative transmitral pressure gradients (TMPG) compared to conventional methods. METHODS: Patient records and intraoperative transesophageal echocardiography (TEE) examinations of 552 consecutive patients undergoing MV repair at a single institution over a three year period were assessed. After separation from cardiopulmonary bypass (CPB), peak and mean TMPG were recorded for each patient and subsequently analyzed. RESULTS: 84 patients (15%) underwent edge-to-edge MV repair. Peak and mean TMPG were significantly higher compared to gradients in patients undergoing conventional repairs: 10.7 ± 0.5 mmHg vs 7.1 ± 0.2 mmHg; P<0.0001 and 4.3 ± 0.2 mmHg vs 2.8 ± 0.1 mmHg; P<0.0001. Only patients with mean TMPG ≥ 7 mmHg (n = 9) required prompt reoperation for iatrogenic mitral stenosis (MS). No differences in peak and mean TMPG were observed among edge-to-edge repairs performed in isolation, compared to those performed in combination with annuloplasty: 11.0 ± 0.7 mmHg vs 10.3 ± 0.6 mmHg and 4.4 ± 0.3 mmHg vs 4.3 ± 0.3 mmHg. There were no differences in TMPG between various types of annuloplasty techniques used in combination with the edge-to-edge repairs. CONCLUSIONS: Edge-to-edge MV repairs are associated with higher intraoperative peak and mean TMPG after separation from CPB compared to conventional repair techniques. Unless gradients are severely elevated, these findings are not necessarily suggestive of iatrogenic MS. Thus, in the immediate postoperative period mildly elevated TMPG can be expected and tolerated after edge-to-edge mitral repairs.
No takes yet. Share an insight, caveat, or question.
Hilberath et al. (2013) conducted a cohort in Mitral regurgitation (n=552). Edge-to-edge mitral valve repair vs. Conventional mitral valve repair was evaluated on Peak transmitral pressure gradient (TMPG) (p=<0.0001). Edge-to-edge mitral valve repair resulted in significantly higher intraoperative peak (10.7 vs 7.1 mmHg) and mean (4.3 vs 2.8 mmHg) transmitral pressure gradients compared to conventional repair.
Synapse has enriched 10 related papers. Consider them for comparative context: