Key result
ABI shows ~88% overall accuracy for PAD screening in diabetes but misses many cases.
Why the study?
Does ankle-brachial index accurately screen for peripheral arterial disease compared to duplex ultrasound in individuals with diabetes mellitus?
Observational (n=99)
Does ankle-brachial index accurately screen for peripheral arterial disease compared to duplex ultrasound in individuals with diabetes mellitus?
Answers are grounded in this paper and cite their sources.
ABI has high specificity but limited sensitivity for detecting PAD in patients with diabetes, suggesting that a normal ABI does not rule out PAD and complementary diagnostic approaches may be needed.
Although the ankle-brachial index (ABI) presents overall satisfactory accuracy, its sensitivity in the context of screening strategies does not ensure the detection of all individuals with peripheral arterial disease (PAD), especially in clinical situations where there is calcification of the arterial media layer. This study evaluated the accuracy of ABI in screening PAD among individuals with diabetes mellitus (DM) in a community setting. An observational study included only individuals with DM. ABI measurement was performed, and the lower limb duplex ultrasound (DU) was used as the reference standard for PAD diagnosis. Sensitivity, specificity, positive and negative predictive values (PPV and NPV), and positive and negative likelihood ratios (LR+ and LR-) of ABI were assessed. The analysis included 194 limbs from 99 participants, with a PAD prevalence identified by DU of 15.98%. ABI demonstrated an accuracy of 87.63%, with a sensitivity of 35.48%, specificity of 97.55%, PPV of 73.33%, NPV of 89.83%, LR+ of 14.46, and LR- of 0.66. ABI showed high specificity but limited sensitivity in detecting PAD among individuals with DM in a community setting. An LR- of 0.66 suggests that a normal ABI result reduces but does not eliminate the possibility of PAD, highlighting the importance of complementary diagnostic approaches to enhance accuracy in identifying PAD in high-risk patients, such as those with DM. Incorporating additional diagnostic methods may be necessary to improve the effectiveness of PAD screening in this group.
No takes yet. Share an insight, caveat, or question.
Cerqueira et al. (2024) conducted an observational in Diabetes mellitus and peripheral arterial disease (n=99). Ankle-brachial index (ABI) vs. Lower limb duplex ultrasound (DU) was evaluated on Accuracy of ABI in screening PAD (Accuracy 87.63%, sensitivity 35.48%, specificity 97.55%). Ankle-brachial index for peripheral arterial disease screening in diabetes showed an accuracy of 87.63%, with high specificity but limited sensitivity compared to duplex ultrasound.
Synapse has enriched 10 related papers. Consider them for comparative context: