Key result
KairoSight-3.0 software matches manual mapping with ~97% accuracy for action potential and calcium transient durations.
Why the study?
Analysis of complex optical datasets in cardiac optical mapping is time-intensive and technically challenging.
KairoSight-3.0 is a validated, semi-automated software package that accurately characterizes cardiac electrophysiology and calcium handling from optical mapping data.
May streamline preclinical optical mapping analysis; human validation required before clinical use.
Cardiac optical mapping is an imaging technique that measures fluorescent signals across a cardiac preparation. Dual optical mapping of voltage-sensitive and calcium-sensitive probes allow for simultaneous recordings of cardiac action potentials and intracellular calcium transients with high spatiotemporal resolution. The analysis of these complex optical datasets is both time intensive and technically challenging; as such, we have developed a software package for semi-automated image processing and analysis. Herein, we report an updated version of our software package (KairoSight-3.0) with features to enhance characterization of cardiac parameters using optical signals. To test software validity and applicability, we used Langendorff-perfused heart preparations to record transmembrane voltage and intracellular calcium signals from the epicardial surface. Isolated hearts from guinea pigs and rats were loaded with a potentiometric dye (RH237) and/or calcium indicator dye (Rhod-2AM) and fluorescent signals were acquired. We used Python 3.8.5 programming language to develop the KairoSight-3.0 software. Cardiac maps were validated with a user-specified manual mapping approach. Manual maps of action potential duration (30 or 80 % repolarization), calcium transient duration (30 or 80 % reuptake), action potential and calcium transient alternans were constituted to validate the accuracy of software-generated maps. Manual and software maps had high accuracy, with >97 % of manual and software values falling within 10 ms of each other and >75 % within 5 ms for action potential duration and calcium transient duration measurements (n = 1000–2000 pixels). Further, our software package includes additional cardiac metric measurement tools to analyze signal-to-noise ratio, conduction velocity, action potential and calcium transient alternans, and action potential-calcium transient coupling time to produce physiologically meaningful optical maps. KairoSight-3.0 has enhanced capabilities to perform measurements of cardiac electrophysiology, calcium handling, and the excitation-contraction coupling with satisfactory accuracy.
No takes yet. Share an insight, caveat, or question.
Haq et al. (2023) studied Cardiac electrophysiology (optical mapping). KairoSight-3.0 software vs. Manual mapping approach was evaluated on Accuracy of software-generated maps compared to manual maps for action potential and calcium transient duration. KairoSight-3.0 software demonstrated high accuracy compared to manual mapping, with >97% of values falling within 10 ms of each other for action potential and calcium transient durations.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: