Key result
Balloon venoplasty successfully recanalized a total occlusion of the brachiocephalic vein and superior vena cava, enabling the implantation of a cardiac resynchronization therapy device.
Why the study?
Implanting physicians need strategies to overcome venous occlusion during cardiac implantable electronic device lead implantation.
Does balloon venoplasty allow successful CIED implantation in patients with total venous occlusion?
Case Report (n=1)
No
Does balloon venoplasty allow successful CIED implantation in patients with total venous occlusion?
Balloon venoplasty is an effective and safe strategy to overcome total venous occlusion during CIED implantation, avoiding the need for more invasive or less optimal pacing strategies.
May enable CIED implantation despite total venous occlusion; hypothesis-generating and should not yet change practice.
This case report describes a successful balloon venoplasty to overcome a total occlusion from the brachiocephalic vein to the superior vena cava in a patient undergoing cardiac resynchronization therapy. It is crucial for implanting physicians to be familiar with strategies to overcome venous occlusion in lead implantation, especially balloon venoplasty, which is an effective and safe approach.
No takes yet. Share an insight, caveat, or question.
Li et al. (2022) conducted a case report in Heart failure with reduced ejection fraction and venous occlusion (n=1). Balloon venoplasty and biventricular pacing CRT implantation was evaluated on Successful lead implantation. Balloon venoplasty successfully recanalized a total occlusion of the brachiocephalic vein and superior vena cava, enabling the implantation of a cardiac resynchronization therapy device.