Key result
An orthogonality-constrained SCNMF noise reduction method improved the signal-to-noise ratio by 1.4 dB and the signal-to-distortion ratio by 2.1 dB compared to the conventional method.
Why the study?
Existing SCNMF-based noise reduction for biological sound sensors attenuated part of the biological sound in addition to noise, necessitating a method with less distortion.
Does an orthogonality-constrained SCNMF method improve signal-to-noise and signal-to-distortion ratios compared to conventional SCNMF in biological sound monitoring?
Does an orthogonality-constrained SCNMF method improve signal-to-noise and signal-to-distortion ratios compared to conventional SCNMF in biological sound monitoring?
The proposed orthogonality-constrained SCNMF method improves noise reduction and reduces distortion in biological sound monitoring compared to conventional methods.
Answers are grounded in this paper and cite their sources.
May improve biological sound monitoring fidelity; leaves open whether it enhances clinical decision-making in cardiovascular care.
The number of deaths due to cardiovascular and respiratory diseases is increasing annually. Cardiovascular diseases with high mortality rates, such as strokes, are frequently caused by atrial fibrillation without subjective symptoms. Chronic obstructive pulmonary disease is another condition in which early detection is difficult owing to the slow progression of the disease. Hence, a device that enables the early diagnosis of both diseases is necessary. In our previous study, a sensor for monitoring biological sounds such as vascular and respiratory sounds was developed and a noise reduction method based on semi-supervised convolutive non-negative matrix factorization (SCNMF) was proposed for the noisy environments of users. However, SCNMF attenuated part of the biological sound in addition to the noise. Therefore, this paper proposes a novel noise reduction method that achieves less distortion by imposing orthogonality constraints on the SCNMF. The effectiveness of the proposed method was verified experimentally using the biological sounds of 21 subjects. The experimental results showed an average improvement of 1.4 dB in the signal-to-noise ratio and 2.1 dB in the signal-to-distortion ratio over the conventional method. These results demonstrate the capability of the proposed approach to measure biological sounds even in noisy environments.
No takes yet. Share an insight, caveat, or question.
Murakami et al. (2021) studied Cardiovascular and respiratory diseases (n=21). Orthogonality-constrained semi-supervised convolutive non-negative matrix factorization (SCNMF) vs. Conventional SCNMF method was evaluated on Signal-to-noise ratio (SNR) and signal-to-distortion ratio (SDR) (1.4 dB SNR improvement, 2.1 dB SDR improvement). An orthogonality-constrained SCNMF noise reduction method improved the signal-to-noise ratio by 1.4 dB and the signal-to-distortion ratio by 2.1 dB compared to the conventional method.