Answers are grounded in this paper and cite their sources.
BACKGROUND: The use of clinical signs, or end-tidal anaesthetic gas (ETAG), may not be reliable in measuring the hypnotic component of anaesthesia and may lead to either overdosage or underdosage resulting in adverse effects because of too deep or too light anaesthesia. Intraoperative awareness, whilst uncommon, may lead to serious psychological disturbance, and alternative methods to monitor the depth of anaesthesia may reduce the incidence of serious events. Bispectral index (BIS) is a numerical scale based on electrical activity in the brain. Using a BIS monitor to guide the dose of anaesthetic may have advantages over clinical signs or ETAG. This is an update of a review last published in 2014. OBJECTIVES: To assess the effectiveness of BIS to reduce the risk of intraoperative awareness and early recovery times from general anaesthesia in adults undergoing surgery. SEARCH METHODS: We searched CENTRAL, MEDLINE, Embase, and Web of Science on 26 March 2019. We searched clinical trial registers and grey literature, and handsearched reference lists of included studies and related reviews. SELECTION CRITERIA: We included randomized controlled trials (RCTs) and quasi-RCTs in which BIS was used to guide anaesthesia compared with standard practice which was either clinical signs or end-tidal anaesthetic gas (ETAG) to guide the anaesthetic dose. We included adult participants undergoing any type of surgery under general anaesthesia regardless of whether included participants had a high risk of intraoperative awareness. We included only studies in which investigators aimed to evaluate the effectiveness of BIS for its role in monitoring intraoperative depth of anaesthesia or potential improvements in early recovery times from anaesthesia. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed studies for inclusion, extracted data, and assessed risk of bias. We assessed the certainty of evidence with GRADE. MAIN RESULTS: = 37%; 5 studies; 26,572 participants; low-certainty evidence). Incidences of intraoperative awareness were one per 1000 in both groups. Only three of five studies reported events, two included participants at high risk of awareness and one included unselected participants, all used a structured questionnaire for assessment and an adjudication process to identify confirmed or definite awareness.One large study (9376 participants) reported a reduced time to discharge from the PACU by a median of three minutes less, and we judged the certainty of this evidence to be low. No studies measured or reported the time to eye opening and the time to orientation.Certainty of the evidenceWe used GRADE to downgrade the evidence for all outcomes to low certainty. The incidence of intraoperative awareness is so infrequent such that, despite the inclusion of some large multi-centre studies in analyses, we believed that the effect estimates were imprecise. In addition, analyses included studies that we judged to have limitations owing to some assessments of high or unclear bias and in all studies, it was not possible to blind anaesthetists to the different methods of monitoring depth of anaesthesia.Studies often did not report a clear definition of intraoperative awareness. Time points of measurement differed, and methods used to identify intraoperative awareness also differed and we expected that some assessment tools were more comprehensive than others. AUTHORS' CONCLUSIONS: Intraoperative awareness is infrequent and, despite identifying a large number of eligible studies, evidence for the effectiveness of using BIS to guide anaesthetic depth is imprecise. We found that BIS-guided anaesthesia compared to clinical signs may reduce the risk of intraoperative awareness and improve early recovery times in people undergoing surgery under general anaesthesia but we found no evidence of a difference between BIS-guided anaesthesia and ETAG-guided anaesthesia. We found six studies awaiting classification and two ongoing studies; inclusion of these studies in future updates may increase the certainty of the evidence.
No takes yet. Share an insight, caveat, or question.
Lewis et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: