Key result
A review of major trials and registries challenges the prerequisite of having an extracorporeal circulation system in the catheterization laboratory during transcatheter aortic valve replacement.
Why the study?
Is an extracorporeal circulation system strictly necessary in the catheterization laboratory during TAVR procedures?
Is an extracorporeal circulation system strictly necessary in the catheterization laboratory during TAVR procedures?
This review challenges the necessity of having an extracorporeal circulation system on standby in the catheterization laboratory during TAVR procedures.
Answers are grounded in this paper and cite their sources.
Questions necessity of extracorporeal circulation standby in TAVR labs; leaves open whether protocols can safely change without prospective trials.
Transcatheter aortic valve replacement (TAVR) is the mainstay for treating high-risk patients with aortic stenosis. As the TAVR procedures worldwide keep increasing, it is inevitable that more issues and complications will arise. Such a complication that merits attention is the conversion of TAVR into open-heart surgery and the necessity this complication creates to have an extracorporeal circulation system in the catheterization laboratory. This review contains an analysis of all major randomized trials and registries on the number and cause of TAVR procedures that ended up in open-heart surgery and presents data to challenge the prerequisite of extracorporeal circulation system in the cath laboratory.
No takes yet. Share an insight, caveat, or question.
Toutouzas et al. (2015) conducted a review in Aortic stenosis. Extracorporeal circulation system was evaluated on Conversion of TAVR into open-heart surgery. A review of major trials and registries challenges the prerequisite of having an extracorporeal circulation system in the catheterization laboratory during transcatheter aortic valve replacement.