This article is devoted to simultaneous displacement and force self-sensing using a single piezoelectric stack actuator. Values of displacement and force are estimated from measurements of charge and applied voltage. To calibrate the self-sensing algorithm, a parameter identification procedure is presented that accounts for hysteresis under varying displacement and force conditions using a standard Prandtl-Ishlinskii hysteresis operator. Quasi-static validation experiments are carried out on a custom-built test rig that shows low average estimation errors of 0.5% and -0.4% with standard deviations of 2.7% and 3.1% in displacement and force, respectively.